Fans for the 8-port PoE+ and PoE++ models

This topic describes the fan modes, temperature and PoE thresholds, and fan log messages for the 8-port PoE+ and PoE++ models.

The following table describes the thresholds and operational properties of the fans for the 8-port PoE+ and PoE++ models. (The temperatures in Fahrenheit are rounded down.)

Table 1. Fan operation properties for the 8-port PoE+ and PoE++ models
Fan Mode M4250-10G2F-PoE+ M4250-10G2XF-PoE+ M4250-10G2XF-PoE++
Off mode
Temp. sensor ≤ 93F (34C) ≤ 97F (36C) ≤ 117F (47C)
PoE budget ≤ 80W ≤ 90W ≤ 45W
Load Full traffic load Full traffic load Full traffic load
Fan use Off Off Off
Quiet mode with fan use below 25% (20% for model M4250-10G2XF-PoE++)
Temp. sensor < 93F (34C) < 97F (36C) < 117F (47C)
PoE budget ≤ 125W ≤ 240W ≤ 200W
Load Full traffic load Full traffic load Full traffic load
Fan use < 25% < 25% < 20%
Quiet mode with fan use from 25 – 100% (20 – 100% for model M4250-10G2XF-PoE++)
Temp. sensor ≥ 93F (34C) ≥ 97F (36C) ≥ 117F (47C)
PoE budget ≤ 125W ≤ 240W 200W – 720W
Load Full traffic load Full traffic load Full traffic load
Fan use ≥ 25 – 100% ≥ 25 – 100% ≥ 20 – 100%
Cool mode with maximum cooling
Fan use 100% 100% 100%

Example of intelligent fan operation:

If the fans of model M4250-10G2F-PoE+ operate in Off mode and either the temperature detected by the temperature sensor exceeds 93F (34C) or the PoE budget exceeds 80W, the switch automatically places the fans in Quiet mode.

Note: In Quiet mode, the fans can temporarily operate at 100 percent speed.

The following table describes the fan operation messages that the switch records in its logs if a temperature threshold is exceeded and the action that occurs if a critical temperature level is exceeded. (The temperatures in Fahrenheit are rounded down.)

Table 2. Temperature thresholds at which fan messages are recorded in the log and action is taken
Message and Action M4250-10G2F-PoE+ M4250-10G2XF-PoE+ M4250-10G2XF-PoE++
Warning ≥ 113F (45C) ≥ 114F (46C) ≥ 141F (61C)
Critical ≥ 118F (48C) ≥ 120F (49C) ≥ 145F (63C)
Shutdown ≥ 127F (53C) ≥ 127F (53C) ≥ 156F (69C)
Temporary shutdown action PoE is disabled. PoE is disabled. PoE is disabled.
The fans are placed in Cool mode. The fans are placed in Cool mode. The fans are placed in Cool mode.
Note: A shutdown action does not shut down the switch but limits the operation of the switch. PoE is disabled and the fans are placed in Cool mode. To return the switch to normal operation, you must restart the switch.