Fans
This topic describes the internal fans, which run in Off, Quiet, or Cool mode depending on temperature and load.
The switch includes internal fans that support intelligent operation, which enables the switch to automatically start the operation of the fans, gradually increase the speed of the fans, and either halt PoE or block traffic if the temperature exceeds a critical level.
The fans support the following modes:
-
Off : The fans are off and produce no noise. This mode is not supported on all models. For models that support this mode, you can only manually set the fans in Off mode (see below).
-
Quiet: The fans function with variable speeds, depending on the temperature, traffic load, and use of the PoE budget. The fan speed can temporarily reach 100 percent. Quiet mode is the default mode. At 25 or 30 percent speed, the fans produce minimal noise. Fan noise increases at 50 percent speed and even more so at 75 percent speed. At 100 percent speed, the fans produce considerable noise.
-
Cool: The fans consistently function at 100 percent speed, provide maximum cooling, and produce considerable noise.
In Quiet mode, the switch might automatically change back and forth between Cool mode and Quiet mode until a temperature, PoE budget, or traffic load condition returns within thresholds.
You can manually control the fans through either the audio-video (AV) local browser user interface (UI) or the command-line interface (CLI). For more information about manually controlling the fans, see the following manuals, which you can download by visiting netgear.com/support/download:
-
Audio-video user manual
-
CLI reference manual
-
PoE+ desktop model: Either the temperature detected by the temperature sensor or sensors exceeds its threshold or a PoE budget is exceeded.
-
PoE+ and PoE++ models: Either the temperature detected by the temperature sensor or sensors exceeds its threshold or a PoE budget is exceeded.
- LED tiles model (M4250-12M2XF): Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.
-
Aggregation model (M4250-16XF): Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.