Fans for the 24-port PoE+ and PoE++ models

This topic describes the fan modes, temperature and PoE thresholds, and fan log messages for the 24-port PoE+ and PoE++ models.

The following table describes the thresholds and operational properties of the fans for the 24-port PoE+ and PoE++ models. (The temperatures in Fahrenheit are rounded down.)

Table 1. Fan operation properties for the 24-port PoE+ and PoE++ models
Fan Mode M4250-26G4F-PoE+ M4250-26G4XF-PoE+ M4250-26G4F-PoE++
Off mode

Temp. sensor 1 or

Temp. sensor 2

≤ 109F (43C)

≤ 116F (47C)

≤ 105F (41C)

≤ 114F (46C)

Off mode is not supported
PoE budget ≤ 45W ≤ 45W
Load Maximum 8 Ethernet ports active. SFP ports not active. Maximum 8 Ethernet ports active. SFP+ ports not active.
Fan use Off Off
Quiet mode with fan use below 30%

Temp. sensor 1 or

Temp. sensor 2

< 111F (44C)

< 118F (48C)

< 107F (42C)

< 116F (47C)

< 102F (39C)

< 105F (41C)

PoE budget ≤ 300W ≤ 480W ≤ 420W
Load Full traffic load Full traffic load Full traffic load
Fan use < 30% < 30% < 30%
Quiet mode with fan use from 30–100%

Temp. sensor 1 or

Temp. sensor 2

111F (44C) – 123F (51C)

118F (48C) – 125F (52C)

107F (42C) – 118F (48C)

116F (47C) – 123F (51C)

102F (39C) – 123F (51C)

105F (41C) – 127F (53C)
PoE budget ≤ 300W ≤ 480W 420W – 1440W with both power supplies active.
Load Full traffic load Full traffic load Full traffic load
Fan use ≥ 30 – 100% ≥ 30 – 100% ≥ 30 – 100%
Cool mode with maximum cooling
Fan use 100% 100% 100%

Example of intelligent fan operation:

If the fans of model M4250-26G4F-PoE+ operate in Off mode and either the temperature detected by the temperature sensor 2 exceeds 116F (47C) or the PoE budget exceeds 45W, the switch automatically places the fans in Quiet mode.

Note: In Quiet mode, the fans can temporarily operate at 100 percent speed.

The following table describes the fan operation messages that the switch records in its logs if a temperature threshold is exceeded and the action that occurs if a critical temperature level is exceeded. (The temperatures in Fahrenheit are rounded down.)

Table 2. Temperature thresholds at which fan messages are recorded in the log and action is taken
Message and Action M4250-26G4F-PoE+ M4250-26G4XF-PoE+ M4250-26G4F-PoE++
Warning

Temp. sensor 1 or

Temp. sensor 2

≥ 125F (52C)

≥ 131F (55C)

≥ 125F (52C)

≥ 136F (58C)

≥ 131F (55C)

≥ 140F (60C)

Critical

Temp. sensor 1 or

Temp. sensor 2

≥ 129F (54C)

≥ 136F (58C)

≥ 134F (57C)

≥ 147F (64C)

≥ 140F (60C)

≥ 150F (66C)

Shutdown

Temp. sensor 1 or

Temp. sensor 2

≥ 132F (56C)

≥ 143F (62C)

≥ 143F (62C)

≥ 158F (70C)

≥ 149F (65C)

≥ 163F (73C)

Temporary shutdown action PoE is disabled. PoE is disabled. PoE is disabled.
The fans are placed in Cool mode. The fans are placed in Cool mode. The fans are placed in Cool mode.
Note: A shutdown action does not shut down the switch but limits the operation of the switch. PoE is disabled and the fans are placed in Cool mode. To return the switch to normal operation, you must restart the switch.