View detailed information about the PTP boundary clock
You can view detailed information about the status of the PTP boundary clock and PTP domains on the switch.
To view detailed information about the status of the PTP boundary clock and PTP domains:
The following table describes the view-only fields on the page.
|
Field |
Description |
|---|---|
|
PTP Parent, Parent Clock |
|
|
Clock Identity |
The clock identity value of the parent clock. |
| Offset |
The offset scaled log variance of the parent clock. |
|
Clock Phase Change Rate |
The phase change rate value of the parent clock. |
|
PTP Parent, Grandmaster Clock |
|
|
Clock Identity |
The clock identity value of the grandmaster clock. |
|
Clock Class |
The clock class value of the grandmaster clock. |
|
Clock Accuracy |
The clock accuracy value of the grandmaster clock. |
| Offset |
The offset scaled log variance of the grandmaster clock. |
| Priority1 |
The configured priority 1 value of the grandmaster clock. |
| Priority2 |
The configured priority 2 value of the grandmaster clock. |
|
PTP Boundary-clock |
|
|
PTP Device Type |
The PTP device type, which can be ordinary clock, transparent clock, or boundary clock. |
|
PTP Device Profile |
The device profile, which is the profile for a specific device in a specific network. |
|
PTP Clock Role Type |
The boundary clock role can be master clock or time-receiver clock. |
|
Clock Operation Mode |
The configured PTP boundary clock operation mode, which can be One-step or Two-step. |
|
Parent Clock Operation Mode |
The parent clock operation mode, which can be N/A for master clock or One-step or Two-step for time-receiver clock. If the status is not known, the filed displays Not available. |
|
Clock Domain |
The configured domain to which the boundary clock belongs. |
|
Number Of PTP Ports |
The number of PTP ports that are available for PTP operation. |
|
Clock Class |
The clock class value of the boundary clock. |
|
Clock Accuracy |
The clock accuracy value of the boundary clock. |
| Offset |
The offset scaled log variance of the boundary clock. |
|
Steps Removed |
The number of hops that the grandmaster clock is removed from the PTP boundary clock. |
|
Mean Path Delay |
The calculated end-to-end delay, which is not applicable to PTP. The field displays 0.0. |
|
PTP Time-properties |
|
|
Current UTC Offset |
The Coordinated Universal Time (UTC) offset value. |
|
Leap59 |
1 indicates that the last minute of the day contains 59 seconds. 0 indicates that the time scale is not PTP. |
|
Leap61 |
1 indicates that the last minute of the day contains 61 seconds. 0 indicates that time scale is not PTP. |
|
Current UTC Offset Valid |
1 indicates that the Current UTC offset value, Leap59 value, and Leap61 value are known to be correct. 0 indicates that these values are not known or not known to be correct. |
|
PTP Timescale |
1 indicates that the PTP time scale is traceable to a primary reference. 0 indicates that the PTP time scale is not traceable. |
| Time Traceable | 1 indicates that the time scale is traceable to a primary reference. 0 indicates that the time scale is not traceable. |
| Frequency Traceable |
1 indicates that the frequency determining the time scale is traceable to a primary reference. 0 indicates that the frequency determining the time scale not traceable. |
|
Time Source |
The source of the time that is used by the GM PTP instance. |
|
PTP Path-trace |
|
|
Clock Identity |
A path trace is the route that a PTP announce message takes through the network path of boundary clocks and is tracked through the path trace TLV in the announce message. The path trace sequence contains the clock identity of each boundary clock that an announce message traverses. |