Manage PTP multiple domains
Precision Time Protocol multiple-domain (PTP-MD) allows a single switch to host multiple instances of PTP BC simultaneously. A switch can host an SMPTE profile along with an AES67 profile, with a connected grandmaster for each profile, or acting as a grandmaster for any of the profiles. You can create up to 4 PTP domains using the following profiles:
- Default: The default PTP settings are used. This is the default setting.
- AES67: A clock profile for connecting audio devices over a common PTP profile.
- SMPTE-2059-2: A clock profile for video traffic.
- AES-R16-2016: A clock profile that interoperates between SMPTE and AES67 clock profiles.
Multiple PTP Boundary Clock (PTP BC) instances in a switch are distinguished by their domain identifiers.
You must configure the profile with a unique domain ID, or associate it with a unique VLAN.
Note: You can associate each PTP BC instance, or domain, with a VLAN. Multiple domains can share a VLAN, or each use a different one, but a domain maps to only one VLAN. The egress port's VLAN membership determines whether PTP control packets leave tagged or untagged, not the domain-to-VLAN association. When each BC instance uses a distinct VLAN carried as a tagged member on a shared trunk port, a physical port or a LAG, that port can carry PTP control packets for multiple BC instances, separated by VLAN.