Manage the PTP domain, boundary clock, and grandmaster clock settings

By default, the PTP boundary clock and grandmaster clock mode is disabled on the switch. You can enable the mode and configure the settings on your PTP domain.

To manage the PTP domain configuration settings:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select System > Management > PTP > PTP Domain Configuration.

    The PTP Domain Configuration page displays.

  3. Select the domain from the Domain menu.
  4. In the Local Clock Priority1 field, enter a priority value from 0 to 255. The priority 1 determines which switch that is capable of functioning as a grandmaster clock is elected to be the active grandmaster clock in the network.
  5. In the Local Clock Priority2 field, enter a value from 0 to 255. The priority 2 also determines which switch that is capable of functioning as a grandmaster clock is elected to be the active grandmaster clock in the network.
  6. Depending on your network needs, select one of the following radio buttons for a PTP clock profile:
    • None: The PTP profile is removed.
    • Default: The default PTPv2 settings are used. This is the default setting. AES67: A clock profile for connecting audio devices over a common PTP profile.
    • SMPTE-2059-2: A clock profile for video traffic.
    • AES-R16-2016: A clock profile that interoperates between SMPTE and AES67 clock profiles.
  7. In the Announce Interval field, enter the period between successive Announce messages in logarithm to base 2 format.

    Announce messages help to elect the best grandmaster clock in the network. The following are the supported ranges and default settings for the PTP clock profiles:

    • Default: 0 to 4. The default setting is 1.
    • AES67: 0 to 4. The default setting is 1.
    • SMPTE-2059-2: –3 to 1. The default setting is 0.
    • AES-R16-2016: 0 or 1. The default setting is 0.
  8. In the Announce Timeout, enter number of Announce messages that are not acknowledged before the switch determines that the grandmaster clock is not transmitting.

    You can enter a number from 2 to 10. The default setting for all PTP clock profiles is 3. For the AES-R16-2016 profile, the only possible value is 3.

  9. In the Sync Interval field, enter the period between successive Sync messages, in logarithm to base 2 format.

    The following are the supported ranges and default settings for the PTP clock profiles:

    • Default: –1 to 1. The default setting is 0.
    • AES67: –4 to 1. The default setting is –3.
    • SMPTE-2059-2: –7 to –1. The default setting is –3.
    • AES-R16-2016: –4 to 1. The default setting is –3.
  10. In the Delay-request Interval field, enter the period between successive Delay-Request messages from the boundary clock to the grandmaster clock, in logarithm to base 2 format.

    Delay-request messages help to calculate the path delay. The following are the supported ranges and default settings for the PTP clock profiles:

    • Default: 0 to 5. The default setting is 0.
    • AES67: –3 to 5. The default setting is 0.
    • SMPTE-2059-2: –7 to 4. The default setting is –3.
    • AES-R16-2016: –4 to 5. The default setting is –3.
  11. Select the IPv4, IPv6, or L2 Transport radio button to set the transport protocol for use on the communication path.
  12. In the Domain field, enter a value from 0 to 127.

    A PTP domain consists of one of more ordinary or boundary clocks that communicate with each other, and a single grandmaster clock. Although more than one switch can be capable of functioning as a grandmaster in the network, only one switch can the active grandmaster clock.

  13. From the PTP Logging Level menu, select the logging level for the PTP state transitions and status.

    The options are Emergency, Alert, Critical, Error, Warning, Notice (the default setting), Info, and Debug. Log messages with the selected severity level and all log messages of greater severity are logged. For example, if you select Warning, the logged messages include Warning, Error, Critical, Alert, and Emergency.

  14. Select the PTP Path-trace Enable or Disable radio button.

    A path trace is the route that a PTP announce message takes through the network path of boundary clocks and is tracked through the path trace TLV in the announce message. The path trace sequence contains the clock ID of each boundary clock that an announce message traverses. The default is Disable.

  15. Select a Clock Operation Mode radio button:
    • One-step: The clock timestamps the Sync message as it exits the port.
    • Two-step: The clock timestamps the Sync message as it exits the port and then immediately follows up with another message that captures the egress timestamp of the Sync message. This is the default setting.
    Note: Do not mix one-step and two-step clock operating modes in different PTP domains.
  16. In the IPv6 Multicast Destination Scope field, type the IPv6 multicast destination scope for the boundary or grandmaster clock.

    By default, the IPv6 multicast destination scope is 0xE.

  17. Select the 2.0 or 2.1 radio button to set the PTP version.
    The default PTP version is 2.1.
  18. In the PTP VLAN field, enter a PTP VLAN for a given domain identifier.
  19. Click the Apply button.

    Your settings are saved.

  20. To save the settings to the running configuration, click the Save icon.

The following table describes the view-only fields on the page.

Table 1. PTP global configuration information

Field

Description

PTP process running

Indicates if the PTP process is enabled on the switch.

GrandMaster Capable

Indicates if the switch is capable of becoming a grandmaster clock.

Communication Model

This field is always Multicast.

Local Clock Identity

The ID of the clock, using an EUI-64 assigned number.