Set up a single-tier MLAG between two M4500 series switches

You can manually configure a single-tier MLAG between two M4500 series switches using the controller.

To set up a single-tier MLAG:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the Managed Devices table, click the 3 dots icon next to the switch you want to create the MLAG on, and select Single-Tier MLAG.

    The MLAG Peer Link Configuration page displays.

  6. From the Select Switch menu, select the other M4500 switch to include in the MLAG.
    Note: Both M4500 series switches must be identical models.
  7. Click the Next button.
  8. In the Assign a Domain ID field, enter a domain ID for the MLAG.
  9. Select the ports to define the peer link of the MLAG, and click the Next button.

    A message displays indicating that the port connections and port channels are successfully verified. If this message does not display, repeat this step.

  10. Click the Submit button.

    A pop up window displays to advise you that when you configure an MLAG, STP (Spanning Tree Protocol) is automatically disabled on the selected ports.

  11. To proceed, click the OK button.

    A message displays indicating that the MLAG peer link configurations are created successfully.

  12. Click the OK button.

    The single-tier MLAG is now created.

    In the Managed Devices table, a green X icon displays in the upper right corner of the M4500 series switch image to indicate the single-tier MLAG configuration. To see the details of the M4500 series switches included in the each MLAG tier or domain, point to the icon.
  13. To save the settings to the running configuration, at the top right of the page, click the Save button.