LED remains solid amber

When you connect the access point to a power source, the LED lights solid amber initially, then blinks amber slowly, and finally turns solid green or solid blue, indicating that the startup procedure is complete and the access point is ready.

If the LED remains solid amber after five minutes, either a boot error occurred or the access point is malfunctioning.

Do the following:

  1. Disconnect the access point from its power source, reconnect it, and wait several minutes to see if the startup procedure completes successfully.
  2. If the startup procedure still does not complete successfully and the LED remains solid amber after five minutes, use the Reset button to return the access point to its factory default settings.

If the access point functions as a PoE PD, see The access point functions as a PoE PD and the LED is blinking green continuously.

If the error persists, a hardware problem might exist. For recovery instructions or help with a hardware problem, contact technical support at netgear.com/support .