LED remains solid amber

If the LED remains solid amber five minutes after the access point started, a boot error occurred or the access point is malfunctioning.

Do the following:

  • Make sure that you are using the correct Ethernet cable, that the cable is correctly inserted a both ends, and that the device at the other end is powered up.

    Use a standard Category 5 Ethernet patch cable. If the network device incorporates Auto Uplink™ (MDI/MDIX) ports, you can use either a crossover cable or a normal patch cable.

  • If the LED remains solid amber, disconnect the access point from its power source, reconnect it, and wait five minutes to see if the startup procedure completes successfully.

  • If the LED still remains solid amber after five minutes, use the Reset button (see Hardware interfaces) to return the access point to its factory default settings.

If the error persists, a hardware problem might exist. For recovery instructions or help with a hardware problem, contact technical support at netgear.com/support .