PoE troubleshooting
Here are some tips for correcting PoE problems that might occur:
- If the PoE Max LED is yellow, disconnect one or more PoE devices to prevent PoE oversubscription. Start by disconnecting the device from the highest-numbered port.
- For each powered device (PD) that is connected to the switch, the associated right port LED on the switch lights solid green. If the right port LED lights yellow, a PoE fault occurred because of one of the conditions listed in the following table.
| PoE fault condition | Possible solution |
|---|---|
| A PoE-related short circuit occurred on the port. | The problem is most likely with the attached PD. Check the condition of the PD, or restart the PD by disconnecting and reconnecting the PD. |
| The PoE power demand of the PD exceeded the maximum level that the switch permits. The maximum level is 15.4W for a PoE connection or 30W for a PoE+ connection, and 60.0W for a PoE++ connection. | |
| The PoE current on the port exceeded the classification limit of the PD. | |
| The PoE voltage of the port is outside the range that the switch permits. | Power cycle the switch to see if the condition resolves itself. |