PoE troubleshooting

Here are some tips for correcting PoE problems that might occur:
  • If the PoE Max LED is yellow, disconnect one or more PoE devices to prevent PoE oversubscription. Start by disconnecting the device from the highest-numbered port.
  • For each powered device (PD) that is connected to the switch, the associated right port LED on the switch lights solid green. If the right port LED lights yellow, a PoE fault occurred because of one of the conditions listed in the following table.
PoE fault condition Possible solution
A PoE-related short circuit occurred on the port. The problem is most likely with the attached PD. Check the condition of the PD, or restart the PD by disconnecting and reconnecting the PD.
The PoE power demand of the PD exceeded the maximum level that the switch permits. The maximum level is 15.4W for a PoE connection or 30W for a PoE+ connection.
The PoE current on the port exceeded the classification limit of the PD.
The PoE voltage of the port is outside the range that the switch permits. Power cycle the switch to see if the condition resolves itself.