Configure SNMPv1 and SNMPv2 trap flags

You can enable or disable specific traps. When the condition that is identified by an active trap occurs on the switch, a trap message is sent to any enabled SNMP trap receivers (also referred to as hosts), and a message is written to the trap log.

To configure the trap flags:

  1. Open a web browser and log in to the device UI using your login details and device admin password.

    The Dashboard page displays.

  2. Select System > Protocols > SNMP > Trap Flags.
    The Trap Flags page displays.
    By default, all of the following trap flags are enabled, and their associated toggles are purple and positioned to the right:
    • Authentication: When enabled, SNMP traps are sent when events involving authentication occur, such as when a user attempts to access the device UI but does not provide a valid user name and password.
    • Link Up/Down: When enabled, SNMP traps are sent when the administrative or operational state of a physical or logical interface link changes.
    • Spanning Tree: When enabled, SNMP traps are sent when various spanning tree events occur.
    • Fan Failure: When enabled, SNMP traps are sent when a fan fails.
  3. To disable a trap flag, click the associated toggle.
    The toggle is gray and positioned to the left.
  4. Click the Apply button.
    Your settings are saved.