PoE troubleshooting (MS510TXUP only)

This topic lists PoE fault conditions and possible solutions.

Here are some tips for correcting PoE problems that might occur:

  • If the PoE Max LED is solid yellow, disconnect one or more PoE devices to prevent PoE oversubscription.
  • For each powered device (PD) that is connected to the switch, the associated PoE LED on the switch lights solid green. If the PoE LED lights solid yellow, a PoE fault occurred and PoE halted because of one of the conditions listed in the following table.
PoE fault condition Possible solution
A PoE-related short circuit occurred on the port. The problem is most likely with the attached PD. Check the condition of the PD, restart the PD by disconnecting and reconnecting the PD, or try a shorter cable.
The PoE power demand of the PD exceeded the maximum level that the switch permits. The maximum level is 15.4W for a PoE connection, 30W for a PoE+ connection, and 60W for a PoE++ connection.
The PoE current on the port exceeded the classification limit of the PD.
The PoE voltage of the port is outside the range that the switch permits. Restart the switch to see if the condition resolves itself. Check the condition of the PD, restart the PD by disconnecting and reconnecting the PD, or try a shorter cable.