Configure PoE settings for the ports

Note: The power limit type is set to class, which means that the port power limit is equal to the class of the attached PD. You cannot change the power limit type.

To configure PoE settings for the ports:

  1. Open a web browser and log in to the device UI using your login details and device admin password.

    The Dashboard page displays.

  2. Select Switching > Ports > POE > POE.

    The POE page displays.

    The following steps refer to the PoE Port Configuration section on the page.

  3. Select one or more interfaces by taking one of the following actions:
    • To configure a single interface, select the check box associated with the interface, or type the interface number (for example, 3g3 mg3 xg3) in the Search field and click the Go button.
    • To configure multiple interfaces with the same settings, select the check box associated with each interface.
    • To configure all interfaces with the same settings, select the check box in the heading row.
  4. Click the Edit button.

    The Edit PoE Port Configuration pop-up window displays.

  5. From the Port Power menu, select the administrative PoE mode of the port:
    • Enable: The port’s capacity to deliver power is enabled. This is the default setting.

    • Disable: The port’s capacity to deliver power is disabled.

  6. From the Port Priority menu, select the priority for the port in relation to other ports if the total power that the switch is capable of delivering exceeds the total power budget:
    • Low: Low priority. This is the default setting.

    • Medium: Medium priority.

    • High: High priority.

    • Critical: Critical priority.

    The port priority determines which ports can still deliver power after the total power delivered by the switch exceeds the total power budget. (In such a situation, the switch might not be able to deliver power to all connected devices.) If the same priority applies to two ports, the lower-numbered port receives higher priority.

  7. From the Power Mode menu, select the PoE mode that the port must function in:
    • 802.3af: The port is powered in and limited to the IEEE 802.3af mode. A PD that requires IEEE 802.3at does not receive power if the port functions in IEEE 802.3af mode.

    • Legacy: The port is powered using high-inrush current, which is used by legacy PDs that require more than 15W to power up.

    • Pre-802.3at: The port is initially powered in the IEEE 802.3af mode and, before 75 msec pass, is switched to the high power IEEE 802.3at mode. Select this mode if the PD does not perform Layer 2 classification or if the switch performs 2-event Layer 1 classification.

    • 802.3at: The port is powered in the IEEE 802.3at mode and is backward compatible with IEEE 802.3af. In this mode, if the switch detects that the attached PD requests more power than IEEE 802.3af but is not an IEEE 802.3at Class 4 device, the PD does not receive power from the switch.

    • Pre-802.3bt: The port supports Class 4 devices that use 4-pair PoE (4PPoE) to receive power higher than 30W but that are not compliant with IEEE 802.3bt. The port also supports the IEEE 802.3at and IEEE 802.3af modes.

    • Pre-802.3bt-lldp: The port supports Class 4 devices that use 4-pair PoE (4PPoE) to receive power higher than 30W (up to the maximum power of 60W) but that are not compliant with IEEE 802.3bt. In this mode, the port allocates the maximum power of 60W to the device. The port also supports the IEEE 802.3at and IEEE 802.3af modes.

    • 802.3bt-type3: The port supports the IEEE 802.3bt Type 3 mode, the IEEE 802.3at mode, and the IEEE 802.3af mode. The 802.3bt-type3 mode is the default mode.

  8. From the Detection Type menu, select how the port detects the attached PD:
    • IEEE 802: The port performs a 4-point resistive detection. This is the default setting.

    • 4pt802.3af +legacy: The port performs a 4-point resistive detection, and if required, continues with legacy detection.

    • Legacy: The port performs legacy detection.

  9. From the Longer Detection Time menu, select if the PoE detection process can last longer than normal:
    • Enable: The port allows a longer PoE detection time to accommodate certain types of PDs that take longer to respond.

    • Disable: The port does not allow a longer PoE detection time.

  10. From the Timer Schedule menu, select a timer schedule or select None, which is the default selection.

    For information about setting up and configuring PoE timer schedules, see PoE timer schedules.

  11. Click the Save button.

    Your settings are saved.

The following table describes the view-only fields on the page.

Table 1. PoE port information

Field

Description

High Power

All ports supports high power mode

Max Power (mW)

The maximum power in milliwatts (mW) that can be provided by the port

Class

The class defines the range of power that a powered device (PD) is drawing from the switch. The class definitions are as follows:

  • 0: 0.44W–16.2W

  • 1: 0.44W–4.2W

  • 2: 0.44W–7.4W

  • 3: 0.44W–16.2W

  • 4: 0.44W–31.6W

  • 5: 0.44W–45.0W

  • 6: 0.44W–60.0W

  • 7: 0.44W–60.0W

  • 8: 0.44W–60.0W

  • Unknown: The class cannot be detected, or no PD is attached to the port

Output Voltage (Volts)

The voltage that is delivered to the PD in volts

Output Current (mA)

The current that is delivered to the PD in milliampere (mA)

Output Power (mW)

The power that is delivered to the PD in milliwatt (mW)

Status

The operational status of the port:

  • Disabled: No power is delivered.

  • Delivering Power. Power is being drawn by the PD.

  • Requesting Power: The port is requesting power.

  • Fault: A problem occurred with the power.

  • Test: The port is in test mode.

  • Other Fault: The port is idle because of an error condition.

  • Searching: The port is not in one of the other states in this list.

Fault Status

The error description when the PoE port is in a fault state:

  • No Error: The port is not in any error state and can provide power.

  • MPS Absent: The port detected the absence of the main power supply, preventing the port from providing power.

  • Short: The port detected a short circuit condition, preventing the port from providing power.

  • Overload: The PD that is connected to the port attempts to draw more power than allowed by the port’s settings, preventing the port from providing power at all.

  • Power Denied: The port was denied power because of a shortage of power or because of an administrative condition. In this condition,