PoE troubleshooting (MS110TXUP only)
This topic lists PoE fault conditions and possible solutions.
Here are some tips for correcting PoE problems that might occur:
- If the PoE Max LED is solid yellow, disconnect one or more PoE devices to prevent PoE oversubscription.
- For each powered device (PD) that is connected to the switch, the associated PoE LED on the switch lights solid green. If the PoE LED lights solid yellow, a PoE fault occurred and PoE halted because of one of the conditions listed in the following table.
| PoE fault condition | Possible solution |
|---|---|
| A PoE-related short circuit occurred on the port. | The problem is most likely with the attached PD. Check the condition of the PD, restart the PD by disconnecting and reconnecting the PD, or try a shorter cable. |
| The PoE power demand of the PD exceeded the maximum level that the switch permits. The maximum level is 15.4W for a PoE connection, 30W for a PoE+ connection, and 60W for a PoE++ connection. | |
| The PoE current on the port exceeded the classification limit of the PD. | |
| The PoE voltage of the port is outside the range that the switch permits. | Restart the switch to see if the condition resolves itself. Check the condition of the PD, restart the PD by disconnecting and reconnecting the PD, or try a shorter cable. |
| Device class | Power delivered | Power allocated |
|---|---|---|
| 0 | 0.44–12.95W | 15.4W |
| 1 | 0.44–3.84W | 4.0W |
| 2 | 3.84–6.49W | 7.0W |
| 3 | 6.49–12.95W | 15.4W |