Configure the global green Ethernet settings

You can configure the global green Ethernet settings.

To configure the global green Ethernet settings:

  1. Open a web browser and log in to the device UI using your login details and device admin password.

    The Dashboard page displays.

  2. Select Switching > Ports > Green Ethernet.

    The Green Ethernet page displays.

  3. Click the Auto Power Down Mode toggle:
    • The toggle is gray and positioned to the left: Auto Power Down Mode is disabled. This is the default setting.
    • The toggle is purple and positioned to the right: Auto Power Down Mode is enabled. If a port link is down, the underlying physical layer goes down for a short period and then checks for port link pulses again so that auto-negotiation remains possible. In this way, the switch saves power when no link partner is present for the port.
  4. Click the EEE Mode toggle:
    • The toggle is gray and positioned to the left: Energy Efficient Ethernet (EEE) Mode is disabled. This is the default setting.
    • The toggle is purple and positioned to the right: EEE Mode is enabled. EEE combines the MAC address of a port with a family of physical layers that support operation in a low power mode. (EEE is defined by the IEEE 802.3az standard.) Lower power mode lets both the send and receive sides of the link disable some functionality for power savings when lightly loaded. Transition to low power mode does not change the link status. Frames in transit are not dropped or corrupted in transition to and from low power mode. Transition time is transparent to upper layer protocols and applications.
  5. Click the Apply button.

    Your settings are saved.