Step 1: Prepare the site

Before you install the switch, make sure that the operating environment meets the site requirements that are listed in the following table.

Table 1. Site requirements

Characteristics

Requirements

Mounting

Desktop installations. Provide a flat table or shelf surface.

Wall installations. Use the wall-mount screws that are supplied with the switch to attach the switch to a wall.

Pole (or other surface) installations. Use an off-the-shelf 75 mm (model GS108Tv3) or 100 mm (models GS110TPv3 and GS110TPP) VESA standard mount to secure the switch to a pole or another surface. The bottom panel of the switch provides two mount holes that are VESA-compliant.

Access

Locate the switch in a position that allows you to access the front panel ports, view the front panel LEDs, and access the power connector on the back panel.

Power source

Use the DC power adapter and power cord that are supplied with the switch. Make sure that the AC outlet is not controlled by a wall switch, which can accidentally turn off power to the outlet and the switch.

Because model GS108Tv3 can function as a PoE powered device (PD), instead of connecting a power adapter, you can let this model receive power from PoE power sourcing equipment (PSE) such as a PoE switch.

Cabling

Route cables to avoid sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures.

Environmental

Temperature. Install the switch in a dry area with an ambient temperature between 32ºF and 104ºF (0ºC and 40ºC). Keep the switch away from heat sources such as direct sunlight, warm-air exhausts, hot-air vents, and heaters.

Operating humidity. The maximum relative humidity of the installation location must not exceed 90 percent, noncondensing.

Ventilation. Do not restrict airflow by covering or obstructing air inlets on the sides of the switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. The room or wiring closet in which you install the switch must provide adequate airflow.

Operating conditions. Keep the switch at least 6 feet (1.83 meters) away from the nearest source of electromagnetic noise, such as a photocopy machine.