System information and statistics commands
Use these M4500 CLI commands to display system information and statistics, including ARP, CPU, event logs, running configuration, hardware, version, and transceivers.
This section describes the commands that use to display system information or statistics.
show arp
This command displays connectivity between the switch and other devices from service port or management port. The Address Resolution Protocol (ARP) cache identifies the MAC addresses of the IP stations communicating with the switch.
| Default | None |
| Format | show arp |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show arp
MAC Address IP Address Interface
------------------- ---------------- ------------
00:00:5E:00:01:03 172.16.3.254 Management
BC:A5:11:F6:4F:8A 172.16.3.98 Management
(M4500-32C) #
show calendar
This command displays the system time.
| Default | None |
| Format | show calendar |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show calendar
show process cpu
This command provides the percentage utilization of the CPU by different tasks.
| Default | None |
| Format | show process cpu |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show process cpu
Memory and Process CPU Utilization Info of Unit:1
Memory Utilization Report
status KBytes
------ ----------
free 1277836
alloc 792756
CPU Utilization:
PID Name 5 Secs 60 Secs 300 Secs
---------- ------------------- -------- -------- --------
10 (rcu_sched) 0.00% 0.06% 0.07%
15 (kworker/1:0) 0.00% 0.01% 0.00%
52 (kworker/0:1) 0.00% 0.01% 0.02%
232 (hwmon0) 0.00% 0.01% 0.02%
613 (procmgr) 0.00% 0.08% 0.09%
720 osapiTimer 0.10% 0.11% 0.12%
729 bcmINTR 0.10% 0.07% 0.06%
730 socdmadesc.0 0.20% 0.14% 0.13%
733 bcmMEM_SCAN.0 0.00% 0.04% 0.07%
735 bcmL2X.0 3.11% 3.47% 3.49%
737 bcmCNTR.0 1.24% 1.50% 1.50%
740 bcmLINK.0 2.80% 2.65% 2.64%
741 bcmRX 0.00% 0.07% 0.07%
742 cpuUtilMonitorTask 0.20% 0.24% 0.25%
744 tL7Timer0 0.00% 0.03% 0.03%
750 simPts_task 0.00% 0.04% 0.04%
753 BootP 0.10% 0.01% 0.00%
760 emWeb 0.10% 0.01% 0.01%
774 hapiBroadBfdCtrlTas 0.31% 0.29% 0.29%
796 dot1s_timer_task 0.00% 0.06% 0.06%
800 radius_task 0.00% 0.02% 0.01%
806 snoopTask 0.00% 0.06% 0.07%
812 SNTP 0.10% 0.01% 0.00%
827 pbrProcessingTask 0.00% 0.01% 0.00%
851 (ospf_app) 0.00% 0.01% 0.02%
888 RMONTask 0.00% 0.21% 0.28%
900 mlagTxTask 0.10% 0.01% 0.00%
924 openrTask 1.66% 1.86% 1.93%
------------------------------ -------- -------- --------
Total CPU Utilization 10.16% 11.30% 11.53%
(M4500-32C) #
show process cpu threshold
This command displays the configurations of CPU utilization threshold.
| Default | None |
| Format | show process cpu threshold |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show process cpu threshold
CPU Utilization Monitoring Parameters
Rising Threshold............................... 90 %
Rising Interval................................ 3600 secs
Falling Threshold.............................. 50 %
Falling Interval............................... 300 secs
CPU Free Memory Monitoring Threshold........... 0 KB
(M4500-32C) #
show eventlog
This command displays the event log, which contains error messages from the system.
| Default | None |
| Format | show eventlog |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show eventlog
Time
File Line TaskID Code yyyy/mm/dd hh:mm:ss
EVENT> Boot! 0 48474A24 AAAAAAAA 2016/06/07 21:22:57
EVENT> Boot! 0 48407104 AAAAAAAA 2016/06/07 17:38:56
EVENT> Manual Reload! 0 48407104 00000000 2016/06/07 17:36:12
EVENT> Boot! 0 48407104 AAAAAAAA 2016/06/07 17:12:40
EVENT> Manual Reload! 0 48407104 00000000 2016/06/07 17:09:45
EVENT> Boot! 0 48407104 AAAAAAAA 2016/06/05 00:04:36
EVENT> Manual Reload Warm! 0 48407104 00000000 2016/06/05 00:01:42
EVENT> Boot! 0 48407104 AAAAAAAA 2016/06/04 23:38:07
EVENT> Manual Reload Warm! 0 48474A24 00000000 2016/06/04 23:35:09
EVENT> Boot! 0 48474A24 AAAAAAAA 2016/06/04 22:01:35
EVENT> Boot! 0 48474A24 AAAAAAAA 2016/06/02 18:09:26
EVENT> Boot! 0 48474A24 AAAAAAAA 2016/06/02 03:26:04
EVENT> Boot! 0 48465024 AAAAAAAA 2016/06/01 21:29:27
EVENT> Clear Event Log! 0 48465024 AAAAAAAA 2016/05/31 23:07:58
(M4500-32C) #
show running-config
This command is used to display/capture the current setting of different protocol packages supported on switch. This command displays/captures only commands with settings/configurations with values that differ from the default value. The output is displayed in script format, which can be used to configure another switch with the same configuration.
The paramenter “<scriptname>” means to redirect the current settings to a script file with an assigned name <scriptname>, which needs a fixed file name extension “.scr”.
The paramenter “all” means to display/capture of all commands with settings/configurations that include values that are same as the default values.
The paramenter “control-plane” means to display the running config of control-plane interface.
The paramenter “mlag” means to display the running config of Multi-Chassis Link Aggregation (MLAG).
| Default | None |
| Format | show running-config [<scriptname> | all | interface {<slot/port> | control-plane | loopback <loopback-id> | port-channel <portchannel-id> | tunnel <tunnel-id> | vlan <vlan-id>} | mlag] |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) #show running-config
!Current Configuration:
!
!System Description "M4500-48XF8C, Runtime Code 7.0.0.1"
!System Software Version "7.0.0.1"
!System Up Time "0 days 0 hrs 9 mins 53 secs"
!Additional Packages BGP-4,QOS,Multicast,IPv6,Routing,Data Center
!Current System Time: Aug 5 03:13:06 2019
!
configure
vlan database
set igmp 1
set igmp fast-leave 1
exit
igmp-plus 1
time-range
username "admin" passwd 7
d32036926a456949a1dd05f3768212c089add94bccd752314f0c05fedf66f52c407256118c62e461710
1230004dff4ee69c4e4d4eaed9590cfd5fe318b39dac3 level 15
username "admin" role "network-admin"
username "guest" role "network-operator"
line console
exit
line vty
exit
line ssh
exit
interface vlan 1
exit
!
interface control-plane
exit
ip igmp snooping
application install orig_restful_api
router ospf
exit
ipv6 router ospf
exit
exit
(M4500-48XF8C) #
show sysinfo
This command displays switch brief information and MIBs supported.
| Default | None |
| Format | show sysinfo |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) #show sysinfo
System Description............................. M4500-48XF8C, Runtime Code 7.0.0.1
System Name.................................... M4500-48XF8C
System Location................................
System Contact.................................
System Object ID............................... 1.3.6.1.4.1.4526.100.3.10
System Up Time................................. 2 days 21 hrs 19 mins 23 secs
MIBs Supported:
RFC 1907 - SNMPv2-MIB The MIB module for SNMPv2 entities
HC-RMON-MIB The original version of this MIB, published
as RFC3273.
HCNUM-TC A MIB module containing textual conventions
for high capacity data types.
SNMP-COMMUNITY-MIB This MIB module defines objects to help
support coexistence between SNMPv1, SNMPv2,
and SNMPv3.
SNMP-MPD-MIB The MIB for Message Processing and
Dispatching
SNMP-TARGET-MIB The Target MIB Module
SNMP-VIEW-BASED-ACM-MIB The management information definitions for
the View-based Access Control Model for SNMP.
SFLOW-MIB sFlow MIB
QNOS-UDLD-MIB UDLD MIB
DIFFSERV-DSCP-TC The Textual Conventions defined in this
module should be used whenever a
Differentiated Services Code Point is used
in a MIB.
QNOS-KEYING-PRIVATE-MIB The Netgear Private MIB for QNOS Keying
Utility
LLDP-EXT-DOT3-MIB The LLDP Management Information Base
extension module for IEEE 802.3
organizationally defined discovery
information.
DISMAN-PING-MIB The Ping MIB (DISMAN-PING-MIB) provides the
capability of controlling the use of the
ping function at a remote host.
QNOS-OUTBOUNDTELNET-PRIVATE-MIB The Netgear Private MIB for QNOS Outbound
Telnet
DISMAN-TRACEROUTE-MIB The Traceroute MIB (DISMAN-TRACEROUTE-MIB)
provides access to the traceroute capability
at a remote host.
RFC 1213 - RFC1213-MIB Management Information Base for Network
Management of TCP/IP-based internets: MIB-II
RFC 2674 - P-BRIDGE-MIB The Bridge MIB Extension module for managing
Priority and Multicast Filtering, defined by
IEEE 802.1D-1998.
RFC 2737 - ENTITY-MIB Entity MIB (Version 2)
RFC 3635 - Etherlike-MIB Definitions of Managed Objects for the
Ethernet-like Interface Types
SWITCHING-EXTENSION-MIB Switching extension - Layer 2
QNOS-PORTSECURITY-PRIVATE-MIB Port Security MIB.
IANAifType-MIB This MIB module defines the IANAifType
Textual Convention
MAU-MIB Management information for 802.3 MAUs.
QNOS-PFC-MIB The MIB definitions Priority based Flow
Control Feature.
QNOS-VPC-MIB The MIB definitions for MLAG.
QNOS-DOT1X-ADVANCED-FEATURES-MIB The Netgear Private MIB for QNOS Dot1x
Advanced Features
QNOS-RADIUS-AUTH-CLIENT-MIB The Netgear Private MIB for QNOS Radius
Authentication Client.
RADIUS-AUTH-CLIENT-MIB RADIUS Authentication Client MIB
QNOS-MGMT-SECURITY-MIB The Netgear Private MIB for QNOS Mgmt
Security
RFC 1850 - OSPF-TRAP-MIB The MIB module to describe traps for the
OSPF Version 2 Protocol.
QNOS-ROUTING-MIB QNOS Routing - Layer 3
IP-MIB The MIB module for managing IP and ICMP
implementations, but excluding their
management of IP routes.
RFC 1657 - BGP4-MIB Definitions of Managed Objects for the
Fourth Version of the Border Gateway
Protocol (BGP-4) using SMIv2
QNOS-QOS-MIB QNOS Flex QOS Support
QNOS-QOS-COS-MIB QNOS Flex QOS COS
RFC 2932 - IPMROUTE-MIB IPv4 Multicast Routing MIB
RFC 5060 - PIM-STD-MIB Protocol Independent Multicast MIB
IANA-RTPROTO-MIB IANA IP Route Protocol and IP MRoute
Protocol Textual Conventions
IPMROUTE-STD-MIB The MIB module for management of IP
Multicast routing, but independent of the
specific multicast routing protocol in use.
RFC 2465 - IPV6-MIB Management Information Base for IP Version
6: Textual Conventions and General Group
RFC 3419 - TRANSPORT-ADDRESS-MIB Textual Conventions for Transport Addresses
QNOS-IPV6-LOOPBACK-MIB The Netgear Private MIB for QNOS Loopback
IPV6 address configuration.
QNOS-DCBX-MIB The MIB module defines objects to configure
DCBX
IEEE8021-CN-MIB Congestion notification module for managing
IEEE 802.1Qau
LLDP-V2-TC-MIB Textual conventions used throughout the IEEE
Std 802.1AB version 2 and later MIB modules.
show system
This command displays switch system information.
| Default | None |
| Format | show system |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) #show system
System description: M4500-48XF8C, Runtime Code 7.0.0.1
System object ID : 1.3.6.1.4.1.4526.100.3.10
System information
System Up time: 2 days, 21 hours, 17 minutes, and 28 seconds
System Name : M4500-48XF8C
System Location :
System Contact :
MAC address : D8-C4-97-B5-6A-BF
Protocol Current : None
(M4500-48XF8C) #
show tech-support
Use this command displays switch system information and configurations when you contact technical support. The output of the show tech-support command combines the output of the following commands: show version, show sysinfo, show interface status, show logging, show event log, show logging buffered, show trap log, show running config, etc.
The parameter “file” means to write the output into a file with file name “TechSupport”.
Other parameters are used to display the information of assigned component.
| Default | None |
| Format | show tech-support [{{bfd | bgp | datacenter | dcvpn | dot1q | dot1s | dot3ad | igmp | layer3 | link_dependency | lldp | log | mcast | mlag | multicast | ospfv2 | ospfv3 | pimsm | routing | sim | snooping | switching | system | vrrp} [file]} | file}] |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) # show tech-support
*************** show version ***************
Switch: 1
System Description............................. M4500-48XF8C, Runtime Code 7.0.0.1
Machine Model.................................. M4500-48XF8C
Serial Number.................................. QTFCU38510002
Burned In MAC Address.......................... BC:A5:11:B5:6A:BF
Software Version............................... 7.0.0.1
Software Storage............................... mSATA
Additional Packages............................ BGP-4
QOS
Multicast
IPv6
Routing
Data Center
OpEN API
Prototype Open API
*************** show sysinfo ***************
System Description............................. M4500-48XF8C
Runtime Code............................. ..... 7.0.0.1
System Name.................................... Switch
System Location................................
System Contact.................................
System Object ID............................... 1.3.6.1.4.1.4526.100.3.10
System Up Time................................. 0 days 2 hrs 43 mins 19 secs
(* note: this command displays information more than 3000 lines, so here we omit
remained messages.)
:
:
(M4500-48XF8C) #
show hardware
This command displays inventory and hardware information for the switch.
| Default | None |
| Format | show hardware |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) #show hardware
Switch: 1
System Description............................. M4500-48XF8C, Runtime Code 7.0.0.1
Machine Model.................................. M4500-48XF8C
Serial Number.................................. QTFCU38510002
Burned In MAC Address..........................
:B5:6A:BF
Software Version............................... 7.0.0.1
Manufacturer Name.............................. QSMC
Date Code...................................... 12/07/2018 00:00:00
FAN 1 Status................................... Active
FAN 1 Airflow Direction........................ Back to Front
FAN 2 Status................................... Active
FAN 2 Airflow Direction........................ Back to Front
FAN 3 Status................................... Active
FAN 3 Airflow Direction........................ Back to Front
FAN 4 Status................................... Active
FAN 4 Airflow Direction........................ Back to Front
FAN 5 Status................................... Active
FAN 5 Airflow Direction........................ Back to Front
FAN 6 Status................................... Active
FAN 6 Airflow Direction........................ Back to Front
Switch Power+ 1................................ Exist
Type........................................... Removable
Model.......................................... ARTESYN
Serial Number.................................. L257VH000Y05P
Revision Number................................ 05
FW Version..................................... 2
Airflow Direction.............................. Back to Front
Switch Power+ 2................................ Exist
Type........................................... Removable
Model.......................................... ARTESYN
Serial Number.................................. L257V2001F05P
Revision Number................................ 05
FW Version..................................... 2
Airflow Direction.............................. Back to Front
Additional Packages............................ BGP-4
............................................... QOS
............................................... Multicast
............................................... IPv6
............................................... Routing
................................................Data Center
............................................... OpEN API
............................................... Prototype Open API
(M4500-48XF8C) #
show version
This command displays inventory, software packages and license key information for the switch.
| Default | None |
| Format | show version |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) #show version
Switch: 1
System Description............................. M4500-48XF8C, Runtime Code 7.0.0.1
Machine Model.................................. M4500-48XF8C
Serial Number.................................. QTFCU38510002
Burned In MAC Address.......................... BC:A5:11:B5:6A:BF
Software Version............................... 7.0.0.1
Software Storage............................... mSATA
Additional Packages............................ BGP-4
............................................... QOS
............................................... Multicast
............................................... IPv6
............................................... Routing
............................................... Data Center
............................................... OpEN API
............................................... Prototype Open API
(M4500-48XF8C) #
show logingsessin
This command displays serial port or remote login connections to the switch.
The parameter “long” means to display full user names of login sessions.
| Default | None |
| Format | show loginsession [long] |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show loginsession
ID User Name Connection From Idle Time Session Time Session Type
---- ------------- --------------------- ---------- ------------ ------------
00 admin EIA-232 00:00:00 02:08:12 Serial
01 guest 172.16.3.68 00:00:05 00:00:05 SSH
(M4500-32C) #
show command filter
All commands starting with keyword “show” can use below parameters to refine output or redirect output to a file. Following any show command to use symbol “|” to set filter and it uses regular expression to math assigned keyword.
The parameter “commands” means any show command of CLI.
The parameter “|” means to use filter option.
The parameter “begin” sets output to begin with the line that matches assigned keyword.
The parameter “exclude” sets output to exclude lines that matches assigned keyword.
The parameter “include” sets output to include lines that matches assigned keyword only.
The parameter “section” sets output to include only a specified section of the content (e.g., “interface 0/1”) with a configurable end-of-section delimiter. If multiple sections matching the specified string match criteria are part of the output, then all instances are displayed. Each section begins with the line containing the starting keyword and ends with the line containing the ending keyword. If there is a line, for example, the line L that contains the starting keyword, and there is no line containing the ending keyword in the original output, the parameter “section” will extract a section from the line L to the final line of the original output. (The default ending keyword is “exit”.)
The parameter “redirect” means to write output to a remote file which locates the assigned “url”, and “url” could be TFTP, FTP or SFTP.
| Default | None |
| Format | show command | {[begin <keyword>] [exclude <keyword>] [include <keyword>][section <starting keyword> [ending keyword]] [redirect url]} |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show interface counters detailed 0/1 | begin "Total Packets" exclude
"0"
Total Packets Received (Octets)................ 438677
Packets Received 64 Octets..................... 115
Packets Received 65-127 Octets................. 376
Packets Received 128-255 Octets................ 2136
Packets RX and TX 64 Octets.................... 117
Packets RX and TX 65-127 Octets................ 36293
Packets RX and TX 128-255 Octets............... 2136
Total Packets Received Without Errors.......... 2729
Multicast Packets Received..................... 2258
Broadcast Packets Received..................... 471
Packets Discarded by Chip Debug Counter........ 225
Total Received Packets Discarded............... 225
Packets Transmitted 64 Octets.................. 2
Packets Transmitted 65-127 Octets.............. 35917
Max Frame Size................................. 1518
Total Packets Transmitted Successfully......... 35919
Multicast Packets Transmitted.................. 35919
MSTP BPDUs Transmitted......................... 33675
(M4500-32C) #
show transceiver device
This command displays summary of digital optical monitor information for the switch.
| Default | None |
| Format | show transceiver device |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show transceiver device
Gigabit Ethernet Vendor Name Vendor Part
Interface Compliance Code Number
---------- ----------------- ----------------- -----------------
0/7 10GBase-SR FINISAR CORP. FTLX8571D3BCL
0/9 10GBase-SR FINISAR CORP. FTLX8571D3BCL
(++) : high alarm, (+) : high warning, (-) : low warning, (--) : low alarm.
mA: milliamperes, dBm: decibels (milliwatts), NA: not available, -: null/unknown.
Temperature Voltage Tx bias current Tx Power Rx Power
Interface (Celsius) (Volts) (mA) (dBm) (dBm)
------------ -------------- ---------- ------------------ ------------ ----------
0/7 23.15 3.31 7.92 -2.17 -2.28
0/9 30.14 3.29 7.95 -1.91 -2.02
…
…
0/51 31.59 3.27 6.88 -23.47 (--) -3.45
0/52 30.77 3.27 6.86 -23.47 (--) -4.15
(M4500-32C) #
show transceiver interface
This command displays detail of digital optical monitor information for the switch.
| Default | None |
| Format | show transceiver interface detail [<intf-range>] |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show transceiver interface detail 0/7
(++) : high alarm, (+) : high warning, (-) : low warning, (--) : low alarm.
mA: milliamperes, dBm: decibels (milliwatts), NA: not available, -: null/unknown.
Interface...................................... 0/7
Gigabit Ethernet Compliance Codes.............. 10GBase-SR
Vendor Name.................................... FINISAR CORP.
Vendor Part Number............................. FTLX8571D3BCL
Vendor Serial Number........................... AP50L3K
Vendor Revision Number......................... A
Vendor Manufacturing Date...................... 2013/02/02
Wavelength..................................... 850 nm
Link length supported for 50um OM2 fiber....... 82 m
Link length supported for 62.5um OM1 fiber..... 33 m
Link length supported for 50um OM3 fiber....... 300 m
Temperature.................................... 34.66 Celsius
Voltage........................................ 3.31 Volts
Tx bias current................................ 8.17 mA
Tx Power....................................... -2.15 dBm
Rx Power....................................... -2.26 dBm
Temperature high alarm threshold............... 80.00 Celsius
Temperature high warning threshold............. 70.00 Celsius
Temperature low warning threshold.............. 0.00 Celsius
Temperature low alarm threshold................ -5.00 Celsius
Voltage high alarm threshold................... 3.46 Volts
Voltage high warning threshold................. 3.40 Volts
Voltage low warning threshold.................. 3.20 Volts
Voltage low alarm threshold.................... 3.14 Volts
Tx bias current high alarm threshold........... 12.00 mA
Tx bias current high warning threshold......... 10.00 mA
Tx bias current low warning threshold.......... 2.00 mA
Tx bias current low alarm threshold............ 0.00 mA
Tx power high alarm threshold.................. 3.97 dBm
Tx power high warning threshold................ 3.49 dBm
Tx power low warning threshold................. -2.50 dBm
Tx power low alarm threshold................... -3.00 dBm
Rx power high alarm threshold.................. 3.97 dBm
Rx power high warning threshold................ 3.49 dBm
Rx power low warning threshold................. -9.50 dBm
Rx power low alarm threshold................... -10.00 dBm
(M4500-32C) #
show process memory
This command provides the memory usage by different tasks.
| Default | None |
| Format | show process memory |
| Mode | Privileged Exec |
Example:
(M4500-32C) #show process memory
Total: 8142492 KB
Allocated: 2451536 KB
Free: 5690956 KB
Component CurrentAllocated[change]
MaxAllocated[Allocs/Frees]
1 - SIM 80904570[ +0] 82085413
[1697/26]
2 - NIM 959361[ +0] 959361 [20/0]
3 - TRAPMGR 1456[ +0] 1456 [1/0]
5 - CNFGR 20868[ +0] 20868 [108/0]
...
177 - COMMAND_SCHEDULER 69728[ +0] 69728 [3/0]
178 - -Unknown- 6720[ +0] 6720 [3/0]
179 - BHD 7484[ +0] 7484 [2/0]
Total Current Usage = 2064220254
osapi Debug overhead = 1928808
(M4500-32C) #
show process app-list
This command displays user and system applications known to the Process Manager.
| Default | None |
| Format | show process app-list |
Example:
(M4500-32C) #show process app-list
Admin Auto Running
ID Name PID Status Restart Status
---- ---------------- ----- --------- --------- --------
1 switchdrvr 31539 Enabled Disabled Running
2 syncdb 31540 Enabled Disabled Running
3 syncdb-test 0 Disabled Disabled Stopped
4 proctest 0 Disabled Enabled Stopped
5 user.start 0 Enabled Disabled Stopped
6 opensshd 32194 Enabled Enabled Running
7 netconf-opensshd 0 Disabled Enabled Stopped
8 vr-agent-0 32059 Enabled Enabled Running
9 ospf-00 32065 Enabled Enabled Running
10 ping-0 32143 Enabled Enabled Running
11 traceroute-0 32150 Enabled Enabled Running
(M4500-32C) #
show process app-resource-list
This command displays the configured and in-use resources of each application known to the Process Manager.
| Default | None |
| Format | show process app-resource-list |
Example:
(M4500-32C) #show process app-resource-list
Memory CPU Memory Max Mem
ID Name PID Limit Share Usage Usage
---- ---------------- ---- ---------- --------- ---------- ----------
1 switchdrvr 31539 Unlimited Unlimited 2047 MB 2047 MB
2 syncdb 31540 Unlimited Unlimited 16 MB 16 MB
3 syncdb-test 0 Unlimited Unlimited 0 MB 0 MB
4 proctest 0 10 MB 20% 0 MB 0 MB
5 user.start 0 Unlimited Unlimited 0 MB 0 MB
6 opensshd 32194 Unlimited Unlimited 1 MB 3 MB
7 netconf-opensshd 0 Unlimited Unlimited 0 MB 0 MB
8 vr-agent-0 32059 Unlimited Unlimited 9 MB 10 MB
9 ospf-00 32065 Unlimited Unlimited 6 MB 7 MB
10 ping-0 32143 Unlimited Unlimited 0 MB 1 MB
11 traceroute-0 32150 Unlimited Unlimited 0 MB 1 MB
(M4500-32C) #
show process proc-list
This command displays the processes started by applications created by the Process Manager.
| Default | None |
| Format | show process proc-list |
Example:
(M4500-32C) (Config)#show process proc-list
Process Application VM Size VM Peak Process
PID Name ID-VRID-Name Chld (KB) (KB) FD Count Up Time
----- --------------- ---------------------------- ------ ------ -------- -------------
31476 procmgr 0-0-procmgr No 0 0 9 0days-3:43:56
31539 switchdrvr 1-0-switchdrvr No 0 0 329 0days-3:43:56
31540 syncdb 2-0-syncdb No 0 0 45 0days-3:43:56
32059 vr_agent_app 8-0-vr-agent-0 No 0 0 21 0days-3:43:50
32065 ospf_app 9-0-ospf-00 No 0 0 18 0days-3:43:50
32143 ping_app 10-0-ping-0 No 0 0 13 0days-3:43:48
32150 traceroute_app 11-0-traceroute-0 No 0 0 13 0days-3:43:48
32194 opensshd 6-0-opensshd No 0 0 7 0days-3:43:43
(M4500-32C) #
show environment
This command displays vital environment status data, including temperature, fan (speed, state), RPSU (temperature, fan speed, state, and power).
| Format | show environment |
| Mode | Privileged EXEC |
Display Message
| Fields | Definition |
|---|---|
| Temp | The current temperature (C). |
| Crit Temp | The maximum limit of temperature. |
| State | The status of module. |
| Max Temp | The highest temperature after the system boot. |
| Type | The type of module (fixed or removable). |
| Speed | The fan speed (RPM). |
| Description | The name of sensor. |
| Power | The power of RPSU (W). |
Example: The following shows examples of the command.
(M4500-32C) #show environment
Temperature Sensors:
Unit Sensor Description Temp (C) Crit_Temp (C) State Max_Temp (C)
---- ------ ------------ --------- -------------- -------- -------------
1 1 Temp-1 36 67 Normal 38
1 2 Temp-2 37 65 Normal 39
1 3 Temp-3 31 61 Normal 32
1 4 Temp-4 26 59 Normal 28
1 5 Temp-5 34 64 Normal 37
1 6 Temp-6 42 76 Normal 44
1 7 Temp-7 31 67 Normal 33
Fans:
Unit Fan Description Type Speed (RPM) State
---- --- -------------- --------- ------------- -------------
1 1 Fan-1 Removable - Failed
1 2 Fan-2 Removable - Failed
1 3 Fan-3 Removable - Failed
1 4 Fan-4 Removable - Failed
1 5 Fan-5 Removable - Failed
1 6 Fan-6 Removable - Failed
1 7 Fan-7 Removable - Failed
1 8 Fan-8 Removable - Failed
1 9 Fan-9 Removable - Failed
1 10 Fan-10 Removable - Failed
1 11 Fan-11 Removable - Failed
1 12 Fan-12 Removable - Failed
Power Modules:
Description Type Temp1 (C) Temp2 (C) Speed (RPM) Power (W) State
------------ ----------- --------- --------- ----------- --------- ------------
PS-1 Removable 28 46 3150 60 Operational
PS-2 Removable 27 45 3000 50 Operational
show configuration files
This command displays the content of text-based configuration files from the CLI. The text-based configuration files (startup-config, backup-config and factory-defaults) are saved compressed in flash. With this command, the files are decompressed while displaying their content.
| Format | show {startup-config | backup-config | factory-defaults} |
| Mode | Privileged EXEC |
| Fields | Definition |
|---|---|
| startup-config | Display the content of the startup-config file. |
| backup-config | Display the content of the backup-config file. |
| factory-defaults | Display the content of the factory-defaults file. |
process cpu threshold
Use this command to configure the CPU utilization thresholds. The Rising and Falling thresholds are specified as a percentage of CPU resources. The utilization monitoring time period can be configured from 5 seconds to 86400 seconds in multiples of 5 seconds. The CPU utilization threshold configuration is saved across a switch reboot. Configuring the falling utilization threshold is optional. If the falling CPU utilization parameters are not configured, then they take the same value as the rising CPU utilization parameters.
| Format | process cpu threshold type total rising <1-100> interval |
no process cpu threshold type total
| Mode | Global Config |
| Parameter | Description |
|---|---|
| rising threshold | The percentage of CPU resources that, when exceeded for the configured rising interval, triggers a notification. The range is 1 to 100. The default is 0 (disabled). |
| rising interval | The duration of the CPU rising threshold violation, in seconds, that must be met to trigger a notification. The range is 5 to 86400. The default is 0 (disabled). The percentage of CPU resources that, when usage falls below this level for the configured interval, triggers a notification. The range is 1 to 100. The default is 0 (disabled). |
| falling threshold | A notification is triggered when the total CPU utilization falls below this level for a configured period of time. The falling utilization threshold notification is made only if a rising threshold notification was previously done. The falling utilization threshold must always be equal or less than the rising threshold value. The CLI does not allow setting the falling threshold to be greater than the rising threshold. |
| falling interval | The duration of the CPU falling threshold, in seconds, that must be met to trigger a notification. The range is 5 to 86400. The default is 0 (disabled). |
memory free low-watermark processor
Use this command to get notifications when the CPU free memory falls below the configured threshold. A notification is generated when the free memory falls below the threshold. Another notification is generated once the available free memory rises to 10 percent above the specified threshold. To prevent generation of excessive notifications when the CPU free memory fluctuates around the configured threshold, only one Rising or Falling memory notification is generated over a period of 60 seconds. The threshold is specified in kilobytes. The CPU free memory threshold configuration is saved across a switch reboot.
| Format | memory free low-watermark processor <1-8142712> |
no memory free low-watermark processor
| Mode | Global Config |
| Parameter | Description |
|---|---|
| low-watermark | When CPU free memory falls below this threshold, a notification message is triggered. The range is 1 to the maximum available memory on the switch. The default is 0 (disabled). |
show supported cardtype
Use this command to display the supported card type(s) information.
| Format | show supported cardtype |
| Mode | Privileged Exec |
Display Message
| Fields | Definition |
|---|---|
| CID | The card index |
| Card Model ID | The model identifier for each card index |
show supported cardtype <cardindex>
Use this command to display the specified card information.
| Format | show supported cardtype <cardindex> |
| Mode | Privileged Exec |
| Parameter | Definition |
|---|---|
| <cardindex> | Specifies a card index (CID) to be displayed. |
Display Message
| Fields | Definition |
|---|---|
| Card Type | The numerical identifier unique to this card hardware |
| Model Identifier | The model identifier for specified card index |
| Card Description | The text describing this card type |
pager
Use this command to enable or disable pager admin mode for current access line.
| Default | Enabled |
| Format | [no] pager |
| Mode | Privileged Exec |
show pager
Use this command to display the pager configuration.
| Format | show pager |
| Mode | Privileged Exec |
Example:
(M4500-48XF8C) #show pager
Pager Admin mode............................... Enable