SNMP Inform Commands

Use this M4500 CLI command to configure SNMP inform messages sent to a specified host.

snmp-server host <host-addr> informs

This command configures informs to be sent to the specified host.

Format snmp-server host <host-addr> informs version 2 <community> [filter <filtername>] [udp-port <1-

65535>] [retries <1-255>] [timeout <1-300>]

Parameter Definition
<host-addr> The IPv4 or IPv6 address of the host to send the inform to.
version 2 Sends SNMPv2 informs.
<community> Community string sent as part of the notification. The range is 1 to 20 characters.
<filtername> The filter name to associate with this host. Filters can be used to specify which informs are sent to this host. The range is 1 to 30 characters.
<udp-port> The SNMP Inform receiver port. The default is port 162.
<retries> The number of times to resend an Inform. The default is 3 attempts. The range is 1 to 255 retries.
<timeout> The number of seconds to wait for an acknowledgement before resending the Inform. The default is 15 seconds. The range is 1 to 300 seconds.
Default None
Mode Global Config

no snmp-server host <host-addr>

This command deletes inform receivers.

Format no snmp-server host <host-addr>
Mode Global Config