Perform a cable test

You can test and display information about the cables that are connected to switch ports.

To perform a cable test:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select Monitoring > Ports > Cable Test.

    The Cable Test page displays.

  3. If a stack is configured, select whether to display the physical interfaces for one switch or for all switches in the stack:
    • Unit ID for a stacked switch: The physical interfaces for the switch with the selected stack unit ID are displayed.

      If no switch stack is configured, the only option is unit ID 1.

    • All: The physical interfaces for all switches in the stack are displayed.

      If no switch stack is configured, the All option does not have any effect.

  4. Select the check boxes that are associated with the physical ports for which you want to test the cables.
  5. Click the Apply button.

    A cable test is performed on the selected interface. The cable test might take up to two seconds to complete. If the port has an active link, the cable status is always Normal. The command returns a cable length estimate if this feature is supported by the PHY for the current link speed. Note that if the link is down and a cable is attached to a 10/100 Ethernet adapter then the cable status might be Open or Short because some Ethernet adapters leave unused wire pairs unterminated or grounded.

The following table describes the view-only fields on the page.

Table 1. Cable Test

Field

Description

Cable Status

Indicates the cable status:

  • Normal: The cable is working correctly.

  • Open: The cable is disconnected or a faulty connector exists.

  • Short: An electrical short exists in the cable.

  • Cable Test Failed: The cable status could not be determined. The cable might in fact be working.

  • Untested: The cable is not yet tested.

  • Invalid cable type: The cable type is unsupported.

Cable Length

The estimated length of the cable in meters. The length is displayed as a range between the shortest estimated length and the longest estimated length. Unknown is displayed if the cable length could not be determined. The cable length is displayed only if the cable status is Normal.

Failure Location

The estimated distance in meters from the end of the cable to the failure location. The failure location is displayed only if the cable status is Open or Short.