Configure nonstop forwarding and display associated information

Nonstop forwarding (NSF) allows a standby management switch to take over if the stack management switch goes down or becomes unavailable.

To configure nonstop forwarding and display associated information:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select System > Stacking > Advanced > NSF Summary.

    The NSF Summary page displays.

  3. Select an Admin Status radio button:
    • Disable: NSF is disabled.

    • Enable: NSF is enabled. This is the default setting. When NSF is enabled, the stack automatically selects a standby management switch based on the stack member settings (see Add a stack member or standby management switch). The stack management switch copies stack information to the standby management switch.

  4. Click the Apply button.

    Your settings are saved.

  5. To save the settings to the running configuration, click the Save icon.
  6. To manually initiate an NSF switchover from the stack management switch to the standby management switch, click the Initiate Failover button.

    The standby management switch becomes the stack management switch.

The following table describes the view-only fields on the page.

Field

Description

NSF Summary section

Operational Status

Indicates if NSF is enabled on the standby management switch

Last Startup Reason

The reason of the most recent NSF switchover:
  • Power On: The stack management switch restarted, for example because of a power cycle or the execution of a reload command, and the standby management switch took over.

  • Cold Admin Move: The stack management switch reset all information without actually restarting, the standby management switch took over and began from a preinitialized state, and no data is retained from before the switchover.

  • Warm Admin Move: You pressed the Initiate Failover button or a CLI command for the standby management switch to take over.

  • Auto Warm: The stack management switch restarted because of a failure and the standby management switch took over.

  • Auto Cold: The standby management switch took over and user data traffic was interrupted. This situation might be caused by multiple failures occurring close together.

Time Since Last Restart

The period since the current management switch became the active management switch. For the standby management switch, the value is set to 0.

Restart In Progress

Indicates if a switchover from the stack management switch to the standby management switch is in progress. A restart is not considered complete until all information is fully reconciled.

Warm Restart Ready

The stack management switch is synchronized with the standby management switch, and the stack management switch can be restarted, if needed.
Copy of Running Configuration to Backup Unit

Status

The status of copying the running configuration to the standby management switch

Time Since Last Copy

The period since the running configuration was copied to the standby management switch
NSF Support on Unit

Unit ID

The unit ID of the switch in the stack

NSF Support

Displays if the switch in the stack is capable of supporting NSF