Manage N+1 power redundancy

If your model provides power supply unit (PSU) bays (also referred to as slots), you can install one or more auxiliary power supplies (APSs) to enable N+1 power redundancy or expand PoE power (see Manage the PoE usage threshold). Depending on the number of PSU bays, you can also do both.

When you enable N+1 power redundancy, the total usable power delivered by all APSs equals the power of all APSs minus the power of one APS. The power load is shared evenly across all APSs, which behave as if they were one large uninterruptible APS. If one APS fails, the two other APSs continue to provide power, allowing all connected powered devices (PDs) to remain powered up.

To manage N+1 power redundancy:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select System > PoE > Advanced > Power Configuration.

    The Power Configuration page displays.

  3. To enable or disable N+1 power redundancy, select one of the following radio buttons:
    • Enable: Enables N+1 power redundancy. The PDs might be powered off if the consumed power exceeds the available power.

    • Disable: Disables N+1 power redundancy. This is the default setting.

  4. Click the Apply button.

    Your settings are saved.

  5. To save the settings to the running configuration, click the Save icon.

The following table describes the view-only fields in the Power Redundancy Configuration section.

Table 1. PoE information

Field

Description

N+1 Active

Displays whether N+1 is enabled (Yes or No)

Number of PSU

The number of connected and active APSs

Effective Number of PSU

The number of connected and active APSs while the N+1 mode is enabled