Manage N+1 power redundancy
If your model provides power supply unit (PSU) bays (also referred to as slots), you can install one or more auxiliary power supplies (APSs) to enable N+1 power redundancy or expand PoE power (see Manage the PoE usage threshold). Depending on the number of PSU bays, you can also do both.
When you enable N+1 power redundancy, the total usable power delivered by all APSs equals the power of all APSs minus the power of one APS. The power load is shared evenly across all APSs, which behave as if they were one large uninterruptible APS. If one APS fails, the two other APSs continue to provide power, allowing all connected powered devices (PDs) to remain powered up.
To manage N+1 power redundancy:
The following table describes the view-only fields in the Power Redundancy Configuration section.
|
Field |
Description |
|---|---|
|
N+1 Active |
Displays whether N+1 is enabled (Yes or No) |
|
Number of PSU |
The number of connected and active APSs |
|
Effective Number of PSU |
The number of connected and active APSs while the N+1 mode is enabled |