Fans
This topic describes the internal fans, their Quiet and Cool modes, and the fan settings for each model.
Each model integrates multiple temperature sensors that automatically regulate the fan speed. A half-width model integrates three internal fans. A full-width model integrates four internal fans.
The switch includes internal fans that support intelligent operation, which enables the switch to automatically start the operation of the fans, gradually increase the speed of the fans, and either halt PoE or block traffic if the internal switch temperature exceeds a critical level.
The fans function with variable speeds, depending on the internal switch temperature, use of the PoE budget, and traffic load. The fan speed can temporarily reach 100 percent.
In Quiet mode, the switch might automatically change back and forth between Cool mode and Quiet mode until the detected internal switch temperature or use of the PoE budget returns within safe operational thresholds. A full traffic load can also cause the internal switch temperature to increase and the fans to function in Cool mode.
The fans support the following modes:
-
Quiet: Quiet mode is the default mode. At approximate 30 percent speed, the fans produce minimal sound. At higher speeds, the sound of the fans becomes more noticeable. At 100 percent speed, the fans produce significant noise.
Table 1. Quiet mode fan settings Model number
PoE Power Load
Fan Duty Range
Room Temp. Range
Internal Switch Temp. (Top)
Acoustic Noise Range
M4350-24G4XF
720W
720W
28 to
60
25°C to
45°C
33.1°C to
48.2°C
33dBA to
52dBA
M4350-48G4XF
1440W
1440W
28 to
60
25°C to
45°C
33.4°C to
48.5°C
33dBA to
52dBA
M4350-24M4X4V
2520W
2520W
30 to
60
25°C to
45°C
29.4°C to
47.3°C
35dBA to
51.5dBA
M4350-44M4X4V
3314W
3314W
28 to
60
25°C to
45°C
43.3°C to
50.1°C
34dBA to
52dBA
M4350-24F4X
N/A
N/A
25 to
70
25°C to
50°C
33.6°C to
54.4°C
30dBA to
59dBA
M4350-8M2V
551W
551W
32 to
65
25°C to
45°C
47.6°C to
56.9°C
33dBA to
51.2dBA
M4350-8X8F
N/A
N/A
27 to
70
25°C to
50°C
34.4°C to
51.7°C
34dBA to
56dBA
M4350-12X12F
N/A
N/A
27 to
100
25°C to
50°C
31.9°C to
51.5°C
34dBA to
64dBA
M4350-24X4V
720W
720W
30 to
70
25°C to
45°C
32.3°C to
46.6°C
35dBA to
57dBA
M4350-24F4V
N/A
N/A
30 to
85
25°C to
50°C
34.2°C to
52.4°C
34dBA to
62dBA
M4350-36X4V
1760W
1760W
25 to
60
25°C to
45°C
39.0°C to
49.2°C
32dBA to
54dBA
M4350-24X8F8V
1770W
1770W
25 to
60
25°C to
45°C
39.9°C to
48.5°C
33dBA to
53dBA
M4350-32F8V
N/A
N/A
25 to
80
25°C to
50°C
35.0°C to
52.1°C
33dBA to
63dBA
M4350-16V4C
N/A
N/A
28 to
60
25°C to
50°C
38.2°C to
56.0°C
36dBA to
55dBA
M4350-40X4C
1676W
1676W
25 to
60
25°C to
45°C
39.9°C to
49.6°C
34dBA to
54dBA
M4350-40F4C
N/A
N/A
25 to
60
25°C to
45°C
34.9°C to
51.7°C
34dBA to
55dBA
M4350-16M4V 1130W 22 to
60
25°C to
40°C
41.5°C to
50.1°C
36dBA to
59dBA
M4350-16C N/A
N/A
22 to
70
25°C to
45°C
32.5°C to
51.2°C
30.4dBA to
60.2dBA
-
Cool: The fans function between 60 and 100 percent speed to provide maximum cooling, and produce significant noise.
Table 2. Cool mode fan settings Model number
PoE Power Load
Fan Duty
Room Temp.
Internal Switch Temp. (Top)
Acoustic Noise
M4350-24G4XF
720W
60
25°C
33.9°C
52dBA
M4350-48G4XF
1440W
60
25°C
31.3°C
52dBA
M4350-24M4X4V
2520W
100
25°C
27.3°C
66dBA
M4350-44M4X4V
3314W
60
25°C
38.3°C
52dBA
M4350-24F4X
N/A
100 25°C
28°C
66.9dBA
M4350-8M2V
551W
100 25°C
28.3°C
59.4dBA
M4350-8X8F
N/A
70
25°C
30.3°C
56dBA
M4350-12X12F
N/A
100 25°C
29.5°C
64dBA
M4350-24X4V
720W
70 25°C
29.6°C
57dBA
M4350-24F4V
N/A
85 25°C
30.3°C
62dBA
M4350-36X4V
1760W
60
25°C
30.4°C
54dBA
M4350-24X8F8V
1770W
60
25°C
31.0°C
53dBA
M4350-32F8V
N/A
80
25°C
28.9°C
63dBA
M4350-16V4C
N/A
60
25°C
30.8°C
55dBA
M4350-40X4C
1676W
60
25°C
33.9°C
54dBA
M4350-40F4C
N/A 100
25°C
28.3°C
69.5dBA
M4350-16M4V 1130W 100
25°C
32.8°C
70.7dBA
M4350-16C N/A 100
25°C
27.9°C
68.7dBA
You can manually control the fans through either the audio-video (AV) user interface (UI) or the command-line interface (CLI). For more information about manually controlling the fans, see the following manuals, which you can download by visiting netgear.com/support/download:
-
Audio-video user manual
-
CLI reference manual
-
PoE+ and PoE++ models: Either the internal switch temperature detected by the temperature sensor or sensors exceeds its threshold or a PoE budget is exceeded.
- Other models: Either the internal switch temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.
If the internal switch temperature detected by a sensor exceeds a threshold, the switch records a fan operation message in its log, and might change from Quiet mode to Cool mode. If the internal switch temperature exceeds a critical threshold and an alarm is generated, the operation of the switch might be limited, and for PoE models, PoE might be disabled. To return the switch to normal operation, you must restart the switch.