Log in to the AV UI over the OOB port

You can configure network information on the IPv4 service port, also referred to as the out-of-band (OOB) port. The OOB port is a dedicated Ethernet port for out-of-band management of the switch. Traffic on this port is segregated from operational network traffic on the switch ports and cannot be switched or routed to the operational network.

By default, no IP address is set for the OOB port, but its DHCP client is enabled so that the port can receive an IP address from a DHCP server in your network.

If the OOB port does not receive an IP address from a DHCP server in your network, the IP address for the port is set to 192.168.0.239 with 255.255.255.0 as the subnet mask. The same occurs if you connect the OOB port directly to a computer and reboot the switch.

For information about setting a fixed IP address for the OOB port, see Set a fixed IP address for the OOB port.

To use IP address 192.168.0.239 of the OOB port to access the switch over the AV UI:

  1. Prepare your computer with a static IP address in the 192.168.0.0 subnet with subnet mask 255.255.255.0.

    For example, use 192.168.0.201 and 255.255.255.0 for your computer.

  2. Connect an Ethernet cable from an Ethernet port on your computer to the OOB port on the switch.
  3. Reboot the switch so that the OOB port is set to its default IP address.
  4. Launch a web browser.
  5. Enter https://192.168.0.239 in the web browser address field:
    The login page displays.
    Note: The default web browser protocol is HTTPS. Do not use HTTP to access the AV UI.
  6. In the Login Name field, enter admin as the user name, in the Password field, enter your local device password, and click the AV UI Login button.
    The first time that you log in, no password is required. However, you then must specify a local device password to use each subsequent time that you log in.

    The password must be 8 to 64 characters in length and must contain at least one uppercase letter, one lowercase letter, and one number. The following special characters are allowed: ! @ # $ % ^ & * ( ).

    To display the password, click the eye icon.

    If, in addition to the AV UI, you are also managing the switch through the Insight Cloud Portal or Insight app, enter the Insight network password for the Insight network to which the switch is added. For more information about the password, see Credentials for the AV UI.

    The Overview page displays.

  7. If you use a switch stack, from the Stack Unit menu at the top of the page, select the switch to configure.