Configure and display the green Ethernet EEE LPI history for an interface
You can configure and display the green Ethernet EEE low-power idle (LPI) history for an interface.
To configure and display the green Ethernet EEE LPI history for an interface:
- Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
The System Information page displays.
- Select System > Management > Green Ethernet > Green Ethernet LPI History.
The Green Ethernet LPI History page displays.
- From the Interface menu, select the interface.
- In the Sampling Interval field, enter the interval at which EEE LPI data is collected.
The range is from 30 to 36000 seconds. The default is 3600 seconds.
- In the Max Samples to Keep field, enter the maximum number of samples to keep.
The range is from 1 to 168.The default is 168.
The Percentage LPI time per Stack field displays the time that the interface was in LPI mode since the EEE counters were reset.
- Click the Apply button.
Your settings are saved.
- To save the settings to the running configuration, click the Save icon.
- To refresh the page, click the Refresh button.
The following table describes the view-only fields.
Table 1. Interface green mode EEE LPI history information Field
Description
Sample No.
The sample index
Time Since The Sample Was Recorded
The period that past since the sample was recorded
Percentage Time spent in LPI mode since last sample
The percentage of time that the interface was in LPI mode since the last sample was recorded
Percentage Time spent in LPI mode since last reset
The percentage of time that the interface was in LPI mode since the EEE counters were reset