PoE Troubleshooting Suggestions
This topic lists PoE fault conditions and the steps to resolve them.
Here are some tips for correcting PoE problems that might occur:
-
Make sure that the PoE Max LED on the front panel of the switch is off. If the PoE Max LED is solid yellow, disconnect one or more PoE devices to prevent PoE oversubscription. Start by disconnecting the device from the highest-numbered port.
-
Make sure that the Ethernet cables are plugged in correctly. For each powered device (PD) that is connected to the switch, the associated port LED on the port card lights the appropriate color (see Port Cards and Port LEDs). If the port LED lights a color that indicates that no PoE power is being delivered, a PoE fault occurred and PoE halted because of one of the conditions that are listed in the following table.
Table 1. PoE fault conditions and possible solutions PoE Fault Condition
Possible Solution
A PoE-related short circuit occurred on the port. The problem is most likely with the attached PD. Check the condition of the PD or restart the PD by disconnecting and reconnecting the PD. The PoE power demand of the PD exceeded the maximum level that the switch permits. The maximum level is 15.4W for a PoE connection or 30W for a PoE+ connection. The PoE current on the port exceeded the classification limit of the PD. The PoE voltage of the port is outside the range that the switch permits. Restart the switch to see if the condition resolves itself.