Set the PoE system usage threshold and power management mode

You can configure a threshold for the PoE usage level at which a trap is sent and you can set the power management mode that the switch uses to deliver power to the requesting powered devices (PDs).

To set the PoE system usage threshold and power management mode:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select System > PoE > Basic > PoE Configuration.

    The PoE Configuration page displays.

  3. In the System Usage Threshold field, enter a number from 1 to 99 to set the threshold level at which a trap is sent if the consumed power exceeds the threshold power.
  4. From the Power Management mode menu, select the power management algorithm that the switch uses to deliver power to the requesting PDs:
    • Static: Select Static to specify that the power allocated for each port depends on the type of power threshold that is configured on the port.

    • Dynamic: Select Dynamic to specify that the power consumption on each port is measured and calculated in real time. This is the default setting.

  5. To set the traps, in the PoE Trap Configuration section, select one of the following radio buttons:
    • Enable: Activates the PoE traps. This is the default setting.

    • Disable: Deactivate the PoE traps.

  6. Click the Apply button.

    Your settings are saved.

  7. To save the settings to the running configuration, click the Save icon.

The following table describes the view-only fields on the page.

Table 1. PoE information

Field

Description

Firmware Version

The firmware version of the PoE software.

Power Status

The power status.

Total Power Available (W)

The maximum power in watts the switch can deliver to all ports.

Threshold Power (W)

If the consumed power is below the threshold power, the switch can power up another port. The consumed power can be between the nominal and threshold power. The threshold power is displayed in watts.

Note: The threshold power value is determined by the value that you enter in the System Usage Threshold field.

Consumed Power (W)

Total power in watts that is being delivered to all ports.