Step 1: Prepare the site

Before you install the switch, make sure that the operating environment meets the site requirements.

Before you install the switch, make sure that the operating environment meets the site requirements that are listed in the following table.

Table 1. Site requirements

Characteristics

Requirements

Mounting

Desktop installations for any model: Provide a flat table or shelf surface.

Rack-mount installations for rack-mount models: Use a 19-inch (48.3-centimeter) EIA standard equipment rack that is grounded and physically secure. You also need the rack-mount kit that is supplied with the switch.

Flat-surface installations for desktop models: Use the mount kit that is supplied with the switch.

Access

Install the switch in a position that allows you to access the back panel ports and access the power connector on the back panel. (Except for the desktop models, system and port LEDs are both on the front panel and back panel.)

Power source

Use the AC power cable or cables that are supplied with the switch. For the desktop models, use the DC power adapter and AC power cable.

Make sure that the AC outlet is not controlled by a wall switch, which can accidentally turn off power to the outlet and the switch.

Cabling

Route cables to avoid sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures.

Environmental

Temperature: Install the switch in a dry area with an ambient temperature that is as follows:

  • PoE models: Between 32ºF and 104ºF (0ºC and 40ºC).

  • Non-PoE models: Between 32ºF and 113ºF (0ºC and 45ºC).

Keep the switch away from heat sources such as direct sunlight, warm-air exhausts, hot-air vents, and heaters.

Operating humidity: The maximum relative humidity of the installation location must not exceed 90%, noncondensing.

Ventilation: Do not restrict airflow by covering or obstructing air inlets on the sides of the switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. The room or wiring closet in which you install the switch must provide adequate airflow.

Operating conditions: Keep the switch at least 6 feet (1.83 meters) away from the nearest source of electromagnetic noise, such as a photocopy machine.