Manage the PoE ports

You can manage PoE ports on the switch through the device UI.

To manage PoE ports through the device UI:

  1. Open a web browser from a computer that is connected to the same network as the switch, or connected directly to the switch through an Ethernet cable.
  2. Enter the IP address that is assigned to the switch.
    A login window opens.
  3. Enter the switch password.

    The password is the one that you specified the first time that you logged in. The password is case-sensitive.

    The HOME page displays.

  4. Select POE.
    The Power over Ethernet (PoE) page displays.
  5. To enable or disable the uninterrupted PoE feature, click the Uninterrupted POE toggle:
    • Disabled: The toggle displays gray.
    • Enabled: The toggle displays green.

    By default, the uninterrupted PoE feature is disabled, causing the switch to stop providing PoE power while it is rebooting. If you enable the uninterrupted PoE feature, the switch continues to provide PoE power to any attached PDs while the switch is rebooting, even if it is rebooting after a regular firmware update.

    However, note the following situations during which the switch temporarily stops providing PoE:

    • The switch reboots because you reset it to factory default settings.
    • The switch reboots because you upgrade the switch firmware with a change in the configuration structure, an update to the chip driver, or a change to the default PoE settings.
  6. On the SETTING menu, open the menu for the port number.

    The port settings display.

  7. Click the EDIT button.
  8. From the Port Power menu, select one of the following options:
    • Enable: The port’s capacity to deliver power is enabled. This is the default setting.
    • Disable: The port’s capacity to deliver power is disabled.
  9. From the Port Priority menu, select the priority for the port in relation to other ports if the total power that the switch is capable of delivering exceeds the total power budget:
    • Low: Low priority. This is the default setting.
    • High: High priority.
    • Critical: Critical priority.

    The port priority determines which ports can still deliver power after the total power delivered by the switch exceeds the total power budget. (In such a situation, the switch might not be able to deliver power to all connected devices.) If the same priority applies to two ports, the lower-numbered port receives higher priority.

  10. From the Power Mode menu, select the PoE mode in which the port must function:
    • 802.3af: The port is powered in and limited to the IEEE 802.3af mode. A PD that requires IEEE 802.3at does not receive power if the port functions in IEEE 802.3af mode.
    • Legacy: The port is powered using high-inrush current, which is used by legacy PDs that require more than 15W to power up.
    • Pre-802.3at: The port is initially powered in the IEEE 802.3af mode and, before 75 msec pass, is switched to the high power IEEE 802.3at mode. Select this mode if the PD does not perform Layer 2 classification or if the switch performs 2-event Layer 1 classification.
    • 802.3at: The port is powered in the IEEE 802.3at mode and is backward compatible with IEEE 802.3af. The 802.3at mode is the default mode. In this mode, if the switch detects that the attached PD requests more power than IEEE 802.3af but is not an IEEE 802.3at Class 4 device, the PD does not receive power from the switch.
  11. From the Power Limit Type menu, select one of the following options:
    • None: The port draws up to Class 0 maximum power in low power mode and up to Class 4 maximum power in high power mode.
    • Class: The port power limit is equal to the class of the attached PD.
    • User: The port power limit is equal to the value that is specified in the Power Limit (W) field. This is the default setting.
    Note: If a PD doesn't report its class correctly, these options can preserve PoE power by preventing the switch from delivering more power than the PD requires. However, depending on which option you select, a PD that doesn't report its class correctly might not power up at all.
    Note: The power limit range is between 3.0 Watts and 30.0 Watts.
  12. From the Detection Type menu, select one of the following options:
    • IEEE 802: The port performs a 4-point resistive detection. This is the default setting.
    • 4pt 802.3af + Legacy: The port performs a 4-point resistive detection, and if required, continues with legacy detection.
    • Legacy: The port performs legacy detection.
  13. Click the APPLY button.
    Your settings are saved.