Install a switch in a rack with rear access using the adjustable brackets

If you can access the rear of the rack, use the following installation instructions.
Note: For visual installation guidelines, see Visual Installation Guide.

To install the switch in a rack using the adjustable brackets:

  1. Assemble the small brackets to the front left and right sides of the switch by inserting the small screws through each small bracket and into the mounting holes in the switch.


  2. Tighten the screws with a Phillips screwdriver to secure each small bracket to the switch.
  3. Insert the small screws provided in the adjustable bracket kit through each torsion hinge and insert them into the rear mounting holes on the switch.
    • For switches that are 1RMU high, install the 400 mm torsion hinges, parts C, one on either side of the switch.


    • For switches that are 2RMU high, install the left torsion hinge, part D, on the left of the switch and install the right torsion hinge, part E, on the right of the switch.


  4. Tighten the screws with a Phillips screwdriver to secure the torsion hinges to the switch.
  5. Assemble the adjustable brackets with the screws


  6. Align the mounting holes in the adjustable brackets with the holes in the rear rack posts.
    Note: Use the same thread mounting screws for the rack thread type.
  7. Align the switch with the adjustable brackets and use the mounting screws to secure the adjustable brackets with a Phillips screwdriver onto the rack.


  8. Insert the switch into the rack from the front of the rack.
    Slide the switch forward until the rear tabs fully engage in the adjustable bracket slots.


  9. Tighten the mounting screws with a Phillips screwdriver to secure the small brackets to the front rack posts.
  10. Tighten the mounting screws on the adjustable brackets with a Phillips screwdriver to secure the brackets to the rear rack posts.
  11. Gently pull the switch up and down to ensure the switch is fully secure in the adjustable brackets. Verify that the switch is level, and check the cable and airflow clearance.