Install two half-width PSU trays in a rack

To install two half-width PSU trays in a single rack space, you need the rack-mount kit supplied with one of the PSU trays. Depending on the depth of the rack, you can install the PSU trays with flush-mounting or set-back mounting in a standard 19 in. wide rack.

To install two single half-width PSU trays in a single rack space:

  1. On the PSU tray that will be at the right side of the rack space, do the following:
    1. On the left side of the PSU tray, insert the washers and four shoulder screws provided in the rack-mount kit of one of the PSU trays.



    2. Tighten the screws with a No. 2 Phillips screwdriver to secure them to the PSU tray. When secured, the screw heads stick out.

  2. On the PSU tray at the left side of the rack space, align the holes on the right side of the PSU tray with the screw heads on the left side of the PSU tray at the right side of the rack.


  3. Insert the screw heads into the holes and slide the left PSU tray back until the two PSU trays are locked and aligned.




  4. Attach the brackets supplied in the mounting kit to the left side of the left PSU tray and to the right side of the right PSU tray by inserting the small screws through each bracket and into the mounting holes in the trays.
    • Flush-mounting example: Use the small brackets with a depth of 2.75 in. (7 cm) and the small screws.

    • Set-back mounting example: Use the medium-sized brackets with a depth of 4.75 in. (12 cm) and the small screws.

  5. Tighten the screws with a No. 1 Phillips screwdriver to secure each bracket to the PSU tray.
  6. Align the mounting holes in the brackets (on the left of the left PSU tray and on the right of the right PSU tray) with the holes in the rack, and depending on the rack, insert the medium-sized or large screws through each bracket and into the rack.
    • Flush-mounting example



    • Set-back mounting example



  7. Tighten the screws with a No. 2 Phillips screwdriver to secure the brackets to the rack.