Monitor port connections or set thresholds at a site using the physical topology

Using the physical topology, you can add the port connections between devices to the monitor, set thresholds for bandwidth utilization, packets errors, and packets drops, and clear counters for traffic statistics.

To monitor port connections, set thresholds, or clear counters at a site:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select Topology.
    The Site Topology page displays. The default topology view is Tree View. To change the default view, see Display and manage the topology for a site.
  5. At the right of the page, click the < (left arrow) icon.

    A menu with icons displays.

  6. Click the topology icon.

    The Topology Views pop-up window displays.

  7. Select the Physical Topology radio button.
  8. As an option, to display the STP configuration, click the Show STP toggle:
    • If display of the STP configuration is enabled, the toggle displays blue or green and is positioned to the right.
    • If display of the STP configuration is disabled, the toggle displays gray and is positioned to the left.
    The topology adjusts.
    Note: If you move to another page in the UI, for example, you select Devices, and then select Topology again, the topology type is reset to the default topology. To set the default topology, see Display and manage the topology for a site.
  9. To close the Topology Views window, at the top right of the window, click the x.
  10. To enable or disable the monitor, do the following:
    • Enable the monitor: Turn on the Show Monitoring toggle so that it displays blue or green and is positioned to the right.

      The monitor table displays. If you did not add any port connections to the monitor, the table is empty.

    • Disable the monitor: Turn off the Show Monitoring toggle so that it displays gray and is positioned to the left.

      The monitor table is hidden.

  11. To manage port connections between devices for the monitor, do the following:
    1. Click a connection dot between two devices.

      A pop-up window with a table displays information about the port numbers and port speeds and connection statistics.

    2. To add the ports or LAGs that form the connection between the devices to the monitor, click the Add to Monitor button.

      The Show Monitoring toggle is automatically enabled so that it displays blue or green and is positioned to the right.

    3. To close the pop-up window, click the x.

      The Site Topology page now displays the monitor, which is a table that shows information about traffic bit rates, physical errors, and dropped packets for the ports that you added in the previous substeps.

    4. To clear the counters for a port or LAG, click the Clear Counters button.
    5. To remove a port or LAG from the monitor, click the trashcan (Delete) icon, and in the Delete Watch List pop-up window that displays, click the Delete button.
  12. To set a threshold for bandwidth utilization, packet errors, packet drops, input power for fiber modules, or output power for fiber modules, do the following:
    1. Click the Set Threshold link.

      The Threshold pop-up window displays.

    2. To set a percentage for bandwidth utilization, physical errors, packet drops, input power for fiber modules, or output power for fiber modules, move each slider to the desired position.

      The settings apply to the entire network.

    3. Click the Apply button.

      Your settings are saved. The pop-up window closes.

  13. To reset all counters on all devices, do the following:
    1. Click the Reset all counters link.

      A Warning pop-up window displays.

    2. Click the Yes button.

      The pop-up window closes.

  14. To display the status of the fiber modules, do the following:
    1. Click the Show Fiber Modules toggle so that it displays blue and is positioned on the right.
      The information in the table adjusts to display the following information for each port with a fiber module:
      • Device Name
      • Port
      • Temp
      • Voltage
      • Output Power
      • Input Power
      • TX Fault
      • LOS
      • Fault Status
      • Supported
      • Vendor Name
    2. Adjust the configurable threshold values for fiber modules by clicking the Set Threshold button and moving each slider to the desired position.

      If a link exceeds or is lower than the preset thresholds, a warning sign displays on the link.

  15. To save the settings to the running configuration, at the top right of the page, click the Save button.