PTP domain and switch status

The PTP Domains page shows whether each domain is applied to the switches of the site, and the status and clock role of each participating switch.

Table 1. Domain status
Status Description What to do
Applied Every online participating switch has the domain with the controller settings. Nothing.
Not Applied At least one online participating switch does not have the domain, or its domain settings differ from the controller settings. The page names the switches. Resync the domain. If the status does not change, check the status of the named switches.

Offline switches are listed separately. An offline switch does not change the status of a domain to Not Applied.

Table 2. Switch status in a domain
Status Description What to do
Applied The switch has the domain with the controller settings. Nothing.
Pending version The switch has the domain, but the IEEE version is not set yet. This can happen while the switch starts the domain. Resync the domain.
Not Applied The switch does not have the domain, or its domain settings were changed outside the controller, for example from the AV UI or the CLI. Resync the domain. The controller settings replace the settings on the switch.
Not Applied, with domain IDs listed All four PTP domain slots on the switch are in use. The listed domain IDs use the slots. Remove a domain that the controller did not create from the switch. For more information, see Manage PTP domains that the controller did not create.
Offline The controller cannot reach the switch. Bring the switch online. Then resync the domain.
Table 3. Clock role of a switch
Role Description
Grandmaster The switch is the time source for the domain.
BC Slave The switch runs as a boundary clock and synchronizes to the grandmaster.

The best master clock algorithm sets the role of each switch. The page reads the role from the switch each time that the table refreshes.