Change the PTP priorities, Source IP, or Clock Operation Mode of a switch

In the table of participating switches for a PTP domain, you can change the Priority 1 and Priority 2 values of a switch for that domain, and the Source IP and Clock Operation Mode of the switch.

The settings in the table apply as follows:

  • Priority 1 and Priority 2 apply to the selected domain only. The best master clock algorithm (BMCA) uses them to select the grandmaster clock. A lower value has a higher priority. You can enter a value from 0 to 255.
  • Source IP and Clock Operation Mode apply to all PTP domains on the switch, including domains that the controller did not create.

The Role column shows whether the switch is the grandmaster clock or a boundary clock in the domain. The BMCA sets the role. You cannot set it directly.

To change the PTP settings of a switch:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select Site Settings > PTP > PTP Domains.

    The PTP Domains page displays the domains of the site, sorted by domain ID, and how many of the four domains are in use.

  5. Select the domain.

    The page displays the VLAN, domain ID, PTP profile, IEEE version, and owning network profile of the domain, and the table of participating switches.

  6. Optional: In the row for the switch, in the Priority 1 and Priority 2 fields, enter values from 0 to 255.

    To make a switch the preferred grandmaster clock, give it a lower Priority 1 value than the other switches.

  7. Optional: In the Source IP field, enter the IPv4 address that the switch uses for PTP messages.

    To clear the Source IP, enter 0.0.0.0. After you save, the field is blank. A blank field means that no Source IP is set, which is a valid setting.

    You cannot enter a link-local address.

  8. Optional: From the Clock Operation Mode menu, select One-Step or Two-Step.

    With one-step, the switch adds the timestamp to the Sync message as the message leaves the port. With two-step, the switch sends the timestamp in a separate follow-up message.

  9. Click the Save button.

    If you changed the Source IP or Clock Operation Mode, a pop-up window warns that the change affects all PTP domains on the switch. Click the button to confirm.

    The controller applies the changes to the switch. If a switch cannot apply a change, the table shows the failure for that switch, and you can try again.