Edit a PTP instance
To edit a PTP instance on your controller:
- Open a web browser and log in to the controller. For more information, see Log in to the controller.
The Dashboard page displays.
- Select Services > PTP > Settings.
The Settings page displays.
- Select the checkbox next to the instance you want to edit and click the Edit button.
The Edit PTP Instance page displays.
- In the Name field, enter a name of up to 32 characters for this instance.
- To enable this instance, click the Admin Mode toggle so that it is positioned to the right.
Admin Mode is enabled by default.
- From the Network menu, select the network to associate with this instance.
- From the VLAN menu, select the VLAN to associate with this instance:
The Ports field automatically populates with the enabled ports from the selected VLAN.
- To manually select ports, click the Ports menu and select one or more ports.
- From the PTPv2 / AVB gPTP Profile menu, select one of the following profiles:
- Default: The default PTPv2 settings are used. This is the default setting.
- AES67: A clock profile for connecting audio devices over a common PTP profile.
- SMPTE-2059-2: A clock profile for video traffic.
- AES-R16-2016: A clock profile that interoperates between SMPTE and AES67 clock profiles.
- 802.1AS AVB: A clock profile for audio video bridging (AVB).
Selecting a profile automatically sets the default values for the timing and transport settings. Some settings are read-only depending on the profile selected.
- In the Local Clock Priority 1 field, enter a value between 0 and 255. The default value is 32. The priority 1 determines which switch that is capable of functioning as a grandmaster clock is elected to be the active grandmaster clock in the network.
- In the Local Clock Priority 2 field, enter a value between 0 and 255. The default value is 32. The priority 2 also determines which switch that is capable of functioning as a grandmaster clock is elected to be the active grandmaster clock in the network.
- In the Announce Interval field, enter the period between successive Announce messages in logarithm to base 2 format.
Announce messages help to elect the best grandmaster clock in the network. The following are the supported ranges and default settings for the PTP clock profiles:
- Default: 0 to 4. The default setting is 1.
- AES67: 0 to 4. The default setting is 1.
- SMPTE-2059-2: –3 to 1. The default setting is 0.
- AES-R16-2016: 0 or 1. The default setting is 0.
- 802.1AS AVB: –5 to 5. The default setting is 0.
- In the Announce Timeout, enter the number of Announce messages that are not acknowledged before the switch determines that the grandmaster clock is not transmitting.
You can enter a number from 2 to 10. The default setting for all PTP clock profiles is 3. For the AES-R16-2016 profile, the only possible value is 3.
- In the Sync Interval field, enter the period between successive Sync messages, in logarithm to base 2 format.
The following are the supported ranges and default settings for the PTP clock profiles:
- Default: –1 to 1. The default setting is 0.
- AES67: –4 to 1. The default setting is –3.
- SMPTE-2059-2: –7 to –1. The default setting is –3.
- AES-R16-2016: –4 to 1. The default setting is –3.
- 802.1AS AVB: –5 to 5. The default setting is –3.
- In the Delay-request Interval or Initial Pdelay Interval (802.1AS only) field, enter the period between successive Delay-Request messages from the boundary clock to the grandmaster clock, in logarithm to base 2 format.
Delay-request messages help to calculate the path delay. The following are the supported ranges and default settings for the PTP clock profiles:
- Default: 0 to 5. The default setting is 0.
- AES67: –3 to 5. The default setting is 0.
- SMPTE-2059-2: –7 to 4. The default setting is –3.
- AES-R16-2016: –4 to 5. The default setting is –3.
- 802.1AS AVB: –5 to 5. The default setting is 0.
- From the Transport menu, set the transport protocol for use on the communication path. Select from one of the following options:
- IPv4: The IPv4 field displays. You can enter an IPv4 address in the IPv4 field.
- L2 Transport.
This setting is read-only for AES67, SMPTE-2059-2, AES-R16-2016, and 802.1AS profiles.
- In the PTP Domain field, enter a PTP domain number. The allowed range is 0 to 127. The default value is 0, except for SMPTE-2059-2 profiles where the default is 127.
- From the PTP Version menu, select 2.0.
- Click the Save button.
Your settings are saved.
The instance displays on the Instances page.