Filter the logs

You can filter logs on the controller.

To filter the log results:

  1. Open a web browser and log in to the controller. For more information, see Log in to the controller.
    The Dashboard page displays.
  2. Select Settings > Diagnostics > Logs.
    The Logs page displays.
  3. Click the Filter button.
  4. From the Severity menu, select from the following options:
    • Emergency: Level 0, the highest warning level. If the device is down or not functioning properly, an emergency log is saved to the device.
    • Alert: Level 1, the second-highest warning level. An alert log is saved if a serious device malfunction occurs, such as all device features being down.
    • Critical: Level 2, the third-highest warning level. A critical log is saved if a critical device malfunction occurs, for example, two device ports are not functioning, while the rest of the device ports remain functional.
    • Error: Level 3, a device error occurred, such as a port being offline.
    • Warning: Level 4, the lowest level of a device warning.
    • Notice: Level 5, provides the network administrators with device information.
    • Informational: Level 6, provides device information. This is the default setting.
    • Debug: Level 7, provides detailed information about the log.
    Note: A log records messages equal to or above a configured severity threshold.
  5. From the Facility menu, select from the following options:
    • System
    • DHCP
    • PTP
    • NTP
    • DNS
    • HTTP
    • mDNS
    • LLDP
  6. From the Time menu, select a start and end time, in hour increments, within seven days from your current date.
  7. Click the Apply button.
    Your settings are saved and the Logs page displays the filtered logs.