Step 1: Prepare the site

Before you install the controller, make sure that the operating environment meets the site requirements that are listed in the following table.

Table 1. Site requirements

Characteristics

Requirements

Mounting

Desktop installations: Provide a flat table or shelf surface.

Rack-mount installations: Use a 19 in. (48.3 cm) EIA standard equipment rack that is grounded and physically secure. You also need the rack-mount kit that is supplied with the controller.

Access

Locate the controller in a position that allows you to access the rear ports, view the front panel LCD screen, access the power connector, and access the SSD card slot.

Power source

Use the AC power cable that is supplied with the controller.

Make sure that the AC outlet is not controlled by a wall controller, which can accidentally turn off power to the outlet and the controller.

Cabling

Route cables to avoid sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures.

Environmental

Temperature: Install the controller in a dry area with an ambient temperature that is between 32ºF and 113ºF (0ºC and 45ºC).

Keep the controller away from heat sources such as direct sunlight, warm-air exhausts, hot-air vents, and heaters.

Operating humidity: The maximum relative humidity of the installation location must not exceed 90%, noncondensing. The minimum humidity requirement is 10%, noncondensing.

Ventilation: Do not restrict airflow by covering or obstructing air inlets on the sides of the controller. Keep at least 2 in. (5.08 cm) free on all sides for cooling. The room or wiring closet in which you install the controller must provide adequate airflow.

Operating conditions: Keep the controller at least 6 ft (1.83 m) away from the nearest source of electromagnetic noise, such as a photocopy machine.