Configure Rapid Spanning Tree Protocol
- On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.
The controller application opens and displays a login page.
- In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.
The Managed Devices page displays.
- If you set up more than one site, from the Site menu, select the site.
The Edit Network Setup pop-up window displays.
Do one of the following:
- Make no changes to the network setup for the site: Click the Apply button.
- Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.
The Managed Devices page adjusts.
- Select Site Settings > Spanning Tree.
The Spanning Tree page displays.
- Select the Engage STP Management toggle to enable STP on the controller.
A confirmation pop-up displays. Click the OK button to allow the controller to synchronize and manage the STP configuration for the site. The service might be interrupted briefly while initial synchronization runs.
- For Spanning Tree Admin Mode, select the Enable radio button to activate spanning tree on the managed switches at the site, or select the Disable button to turn it off.
A confirmation pop-up displays. Click the OK button.
- From the STP Mode menu, select RSTP (802.1w). This is the default option.
A confirmation window displays.
- Click the OK button.
The page adjusts.
- In the Bridge Max Age (Secs) field, enter a numeric value between 6-40.
The default value is 20.
The Bridge Max Age is the maximum time a switch waits without receiving a BPDU before assuming the root bridge fails and triggers a new STP election.
Note: You cannot enter a Bridge Max Age value greater than twice the Bridge Forward Delay minus 1 (2 x (Forward Delay -1)). The controller validates this relationship as you enter values. - In the Bridge Hello Time (Secs) field, enter a numeric value between 1-10.
The default value is 2.
The Bridge Hello Time is the interval at which the root bridge sends Bridge Protocol Data Units (BPDUs) to all other switches in the network.Note: This field is only editable on sites where all switches are M4250 (firmware 13.0.6.x or above) or M4350 (firmware 14.0.9.x or above) models. On sites that do not meet these prerequisites, the Bridge Hello Time field is read-only - In the Bridge Forward Delay (Secs) field, enter a numeric value between 4-30.
The default value is 15.The Bridge Forward Delay is the time a switch spends in the listening and learning states before transitioning a port to the forwarding state.Note: Bridge Max Age must be less than or equal to twice the Bridge Forward Delay minus 1 (2 x (Forward Delay -1)). The controller validates this relationship as you enter values.
- Choose whether to enable or disable the Show Table toggle to view your device settings:
- The toggle is gray and positioned to the left: The table does not show. This is the default setting.
- The toggle is blue and positioned to the right: The table displays the following device information for your devices:
- Device Name
- Device Model
- STP Mode
- Bridge ID
- STP Bridge Priority
- Designated Root Bridge
- Regional Root Bridge
- Topology Change Count
- Time Since Topology Change
- In the Per Switch Configuration table, view the following settings:
- Device Model
- Device Name
- Device MAC Address
- In the Per Switch Configuration table, enter a value between 0-61440 in the Bridge Priority field.
The default setting is 32768. You must enter a value in increments of 4096.
Optionally, click the Auto Suggest Priority button for the controller to suggest an appropriate bridge priority for each switch on your site.
- Click the Apply button.
Your settings are saved.
To cancel your changes and return to the previous settings, click the Cancel button.
To refresh the page, click the Refresh button.Note: All changes are discarded if you click the Refresh before you apply your settings, - To save the settings to the running configuration, at the top right of the page, click the Save button.