Manage PoE port settings

You can manage multiple settings for individual PoE ports.

To manage the PoE port settings:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the table, for the device that you want to configure, click the Configure button.

    The Overview page displays.

  6. Select Power over Ethernet.
    The Power over Ethernet (PoE) page displays.
  7. In the upper right of the page, above the graphical display of the switch, click the PoE Interface Settings link.

    The PoE Interface Settings window displays. By default, PoE is enabled for interfaces.

  8. Select the port or ports to which the settings must apply by clicking individual ports or, to select all ports, select the Select All PoE Ports check box.
  9. Either leave the default PoE mode (802.3at for PoE+ models; 802.3bt for PoE++ models), or, depending on your network devices and requirements, select one of the following modes from the PoE Standard menu:
    • 802.3af: The port is powered in and limited to the IEEE 802.3af mode. A PD that requires IEEE 802.3at does not receive power if the port functions in IEEE 802.3af mode.
    • Legacy: The port is powered using high-inrush current, which is used by legacy PDs that require more than 15W to power up.
    • Pre-802.3at: The port is initially powered in the IEEE 802.3af mode and, before 75 msec pass, is switched to the high power IEEE 802.3at mode. Select this mode if the PD does not perform Layer 2 classification or if the switch performs 2-event Layer 1 classification.
    • 802.3at: The port is powered in the IEEE 802.3at mode and is backward compatible with IEEE 802.3af. The 802.3at mode is the default mode. In this mode, if the switch detects that the attached PD requests more power than IEEE 802.3af but is not an IEEE 802.3at Class 4 device, the PD does not receive power from the switch.

      For PoE+ models, 802.3at is the default setting.

    • Pre-802.3bt: The PoE++ port supports Class 4 devices that use 4-pair PoE (4PPoE) to receive power higher than 30W but that are not compliant with IEEE 802.3bt. The port also supports the IEEE 802.3at and IEEE 802.3af modes.
    • 802.3bt-Type3: The PoE++ port supports the IEEE 802.3bt Type 3 mode, the IEEE 802.3at mode, and the IEEE 802.3af mode.
    • 802.3bt: The PoE++ port is powered in the IEEE 802.3bt mode and is backward compatible with IEEE 802.3at and IEEE 802.3af. In this mode, if the switch detects that the attached PD requests more power than IEEE 802.3at but is not an IEEE 802.3bt device, the PD does not receive power from the switch.

      For PoE++ models, 802.3bt is the default setting.

  10. Either leave the default detection type (4ptdot3af), or, from the Detection Type menu, select how the port detects the attached PD:
    • 4ptdot3af: The port performs a 4-point resistive detection. This is the default setting.
    • 4ptdot3af+legacy: The port performs a 4-point resistive detection, and if required, continues with legacy detection.
    • legacy: The port performs legacy detection.
  11. Either leave the default priority type (Low), or, from the Priority Type menu, select the priority for the port in relation to other ports if the total power that the switch is capable of delivering exceeds the total power budget:
    • Low: Low priority. This is the default setting.
    • Medium: Medium priority.
    • High: High priority.
    • Critical: Critical priority.
  12. Either leave the default power limit type (Class), or, from the Power Limit Type menu, select how the port controls the maximum power that it can deliver:
    • None: For PoE+ (802.3at) ports, the port draws up to Class 0 maximum power in low power mode. In high power mode, the following applies:
      • PoE+ (802.3at) ports: The port draws up to Class 4 maximum power.
      • PoE++ (802.3bt) ports: The port draws up to Class 8 maximum power.
    • Class: The port power limit is equal to the class of the attached PD. This is the default setting. The upper limit is the power that a port can deliver to a PD. The class is detected based on the PD that is attached to the port, and the following applies:
      • PoE+ (802.3at) ports: Possible values are from Class 0 to Class 4.
      • PoE++ (802.3bt) ports: Possible values are from Class 0 to Class 8.
    • User: The port power limit is equal to the value that you specify in the Power Limit (Watts) field.
  13. If you select User from the Power Limit Type, enter the maximum power (in W) that the port can deliver in the Power Limit (Watts) field.

    The power value (in W) that you can enter depends on the physical capacity of the port (which depends on the switch model) and the selection from the PoE Standard menu:

    • 802.3af: The value that you can enter ranges from 3.0W to 18.0W.
    • Legacy: The value that you can enter ranges from 3.0W to 18.0W.
    • Pre-802.3at: The value that you can enter ranges from 3.0W to 32.0W.
    • 802.3at: The value that you can enter ranges from 3.0W to 32.0W.
    • Pre-802.3bt: For PoE++ models, the value that you can enter ranges from 3.0W to 60.0W.
    • 802.3bt-Type3: For PoE++ models, the value that you can enter ranges from 3.0W to 60.0W.
    • 802.3bt: For PoE++ models, the value that you can enter ranges from 3.0W to 99.9W.
  14. If you set up one or more PoE schedules (see PoE schedules), from the PoE Schedule menu, you can select a schedule.
    The default is None, so that no schedule applies.
  15. Click the Apply button.
    Your settings are saved. The window closes. The Power over Ethernet (PoE) page displays again.
  16. To save the settings to the running configuration, at the top right of the page, click the Save button.
  17. To return to the Devices page of the controller, select Devices Management.