Configure flow control for one or more interfaces

You can configure IEEE 802.3x flow control, which can help to prevent data loss when the port cannot keep up with the number of frames being switched:

  • Symmetric flow control: With symmetric flow control, the switch can send a pause frame to stop traffic on the port if the amount of memory used by the packets on the port exceeds a preconfigured threshold and responds to pause requests from partner devices. The paused port does not forward packets for the time that is specified in the pause frame. When the pause frame time elapses, or the utilization returns to a specified low threshold, the switch enables the port to again transmit frames.
  • Asymmetric flow control: With asymmetric flow control, the switch does not send pause frames, but does honor incoming pause frames by temporarily halting transmission.

To configure flow control for one or more ports:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the table, for the device that you want to configure, click the Configure button.

    The Overview page displays.

  6. Select Port configuration.
    The Port Interface Details page displays.
  7. (Single port) To configure flow control for an individual port, do the following:
    1. Select the check box for the port.
    2. From the Flow Control menu for the port, select what happens if the port buffers become full:
      • Disable: The switch does not send pause frames, and data loss could occur. This is the default setting.
      • Symmetric: The switch sends pause frames to stop traffic. The switch also honors incoming pause frames by temporarily halting transmission.
      • Asymmetric: The switch does not send pause frames, and data loss could occur. However, the switch does honor incoming pause frames by temporarily halting transmission.
  8. (Multiple ports) To configure flow control for multiple ports, do the following:
    1. Select the check boxes for the ports.
    2. From the Flow Control menu in the table header row, select what happens if the port buffers become full:
      • Disable: The switch does not send pause frames, and data loss could occur. This is the default setting.
      • Symmetric: The switch sends pause frames to stop traffic. The switch also honors incoming pause frames by temporarily halting transmission.
      • Asymmetric: The switch does not send pause frames, and data loss could occur. However, the switch does honor incoming pause frames by temporarily halting transmission.
  9. (All ports) To configure flow control for all ports, do the following:
    1. Select the check box in the table header row.
    2. From the Flow Control menu in the table header row, select what happens if the port buffers become full:
      • Disable: The switch does not send pause frames, and data loss could occur. This is the default setting.
      • Symmetric: The switch sends pause frames to stop traffic. The switch also honors incoming pause frames by temporarily halting transmission.
      • Asymmetric: The switch does not send pause frames, and data loss could occur. However, the switch does honor incoming pause frames by temporarily halting transmission.
  10. Click the Apply button.

    Your settings are saved.

  11. To save the settings to the running configuration, at the top right of the page, click the Save button.
  12. To return to the Devices page of the controller, select Devices Management.