Manually control the fans

Note: Depending on the M4250 series model, you can control the fans of M4250 series switches. You can also control the fans of any model of the M4350 series switches. You cannot control the fans of the M4300 series switches.

The switch includes internal fans that support intelligent operation, which enables the switch to automatically start the operation of the fans, gradually increase the speed of the fans, and either halt PoE or block traffic if the temperature exceeds a critical level.

You can manually control the fans through either the AV UI (see the following procedure) or the command-line interface (CLI).

For the M4250 series switches, if the fans are functioning in Off mode (which you only can set manually) or in Quiet mode, the switch automatically manages the fans and turns on the fans or gradually increases the speed of the fans under the following conditions:

  • PoE+ and PoE++ models: Either the temperature detected by the temperature sensor exceeds its threshold or a PoE budget is exceeded.
  • LED tiles model (M4250-12M2XF): Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.
  • Aggregation model (M4250-16XF): Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.

For the M4350 series switches, if the fans are functioning in Quiet mode, the switch automatically manages the fans and turns on the fans or gradually increases the speed of the fans under the following conditions:

  • PoE+ and PoE++ models: Either the temperature detected by the temperature sensor or sensors exceeds its threshold or a PoE budget is exceeded.
  • Other models: Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.
Note: For detailed information about temperature thresholds, PoE budgets, and traffic load conditions that affect the fans, see the hardware installation guide, which you can download by visiting netgear.com/support/download.

To manually control the fans:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the table, for the device that you want to configure, click the Configure button.

    The Overview page displays.

  6. In the Fans & Temperature section, select one of the following radio buttons.
    • Off (M4250 series switches only): The fans are off and produce no noise. You can only manually set the fans in Off mode. The following M4250 series models do not support Off mode.
      • M4250-26G4F-PoE++
      • M4250-40G8XF-PoE+
      • M4250-40G8XF-PoE++
    • Quiet: The fans function from 10, 20, or 25 percent (depends on the model) to 100 percent speed. Quiet mode is the default mode. At 10, 20, or 25 percent speed, the fans produce minimal noise. Fan noise increases at 50 percent speed and even more so at 75 percent speed. At 100 percent speed, the fans produce considerable noise.

      In Quiet mode, the switch might automatically change back and forth between Cool mode and Quiet mode until a temperature, PoE budget, or traffic load condition returns within thresholds.

    • Cool: The fans consistently function at 100 percent speed and produce maximum cooling as well as considerable noise.
    The fan setting changes immediately. However, depending on the switch model, if the temperature detected by the temperature sensor exceeds its threshold, a PoE budget is exceeded, or a traffic load condition is exceeded, the switch automatically overrides your manual setting.
  7. To save the settings to the running configuration, at the top right of the page, click the Save button.
  8. To return to the Devices page of the controller, select Devices Management.