The access point functions as a PoE PD and the LED is blinking green continuously

When you connect the access point to a power source, the LED lights solid amber initially, then blinks amber slowly, and finally turns solid green or solid blue, indicating that the startup procedure is complete and the access point is ready.

Do the following:

  1. Disconnect and reconnect the Ethernet cable at the LAN1/PoE+ port on the access point and at the 802.3at (PoE+) port on the PoE+ switch.

    The access point restarts.

  2. If the LED continuous to blink green, check to see why the PoE+ switch cannot provide sufficient PoE power to the access point.

    Most likely, the PoE power budget of the PoE+ switch is oversubscribed and you might need to disconnect another PoE device from the PoE+ switch to make sufficient PoE power available for the access point.