Configure SNTP for the time settings and configure the global SNTP settings

Before you configure SNTP for the time settings, add at least one SNTP server (see Add an SNTP server) that the switch can contact for time keeping.

To configure SNTP for the time settings and configure the global SNTP settings:

  1. Open a web browser and log in to the device UI using your login details and device admin password.

    The Dashboard page displays.

  2. Select System > Management > Time > Time Configuration.

    The Time Configuration page displays.

  3. Select the Clock Source SNTP radio button.

    The default setting is Local.

  4. In the Time Zone Name field, type the name or acronym of the time zone.

    In the Offset Hours and Offset Minutes fields, you can also specify the number of hours and number of minutes that the time zone differs from the Coordinated Universal Time (UTC). The time zone can affect the display of the current system time, for which the default is UTC.

    • Offset Hours: Set the number of hours that the time zone differs from the UTC.

      The range is from –12 to 13 hours. The default is 0 hours

    • Offset Minutes: Set the number of minutes that the time zone differs from the UTC.

      The range is from 0 to 59 minutes. The default is 0 minutes.

    The following steps refer to the SNTP Global Configuration section.

  5. Select a Client Mode radio button to set the operation mode of the SNTP client on the switch:
    • Unicast: SNTP operates in a point-to-point mode. A unicast client sends a request to a designated server at its unicast address and expects a reply from which it can determine the time and, optionally, the round-trip delay and local clock offset relative to the server. For information about adding an SNTP server, see Add an SNTP server.
    • Broadcast: SNTP uses a local broadcast address instead of a multicast address. The broadcast address has a single subnet scope while a multicast address has an internet-wide scope. Broadcast is the default setting.
  6. In the Port field, type the local UDP port on which the SNTP client receives server packets.

    The port number is 123 or in a range from 1025 to 65535. The default is 123. When the default value is configured, the actual client port value used in SNTP packets is assigned by the operating system.

  7. In the Unicast Poll Interval field, type the number of seconds between unicast poll requests expressed as a power of 2.

    The range is from 6 to 10. The default is 6.

  8. In the Broadcast Poll Interval field, type the number of seconds between broadcast poll requests expressed as a power of 2.

    Broadcast messages received prior to the expiration of this interval are discarded. The range is from 6 to 10. The default is 6.

  9. In the Unicast Poll Timeout field, type the number of seconds to wait for an SNTP response to a unicast poll request.

    The range is from 1 to 30. The default is 5.

  10. In the Unicast Poll Retry field, type the number of times to retry a unicast poll request to an SNTP server after the first time-out before the switch attempts to use the next configured server.

    The range is from 0 to 10. The default is 1.

  11. Click the Apply button.