Configure the OUI-based interface settings
You can configure the OUI interface settings.
To configure the OUI-based interface settings:
- Open a web browser and log in to the device UI using your login details and device admin password.
The Dashboard page displays.
- Select Switching > VLAN > Auto-VLAN > OUI-based Auto-VLAN.
The OUI-based Auto-VLAN page displays.
The following steps refer to the OUI Port Settings section.
- From the Filter By menu, select to display ports only (Ports), LAGs only (LAG), or both ports and LAGs (All).
- Select one or more interfaces by taking one of the following actions:
- To configure a single interface, select the check box associated with the interface, or type the interface number (for example, 3g3 mg3 xg3) in the Search field and click the Go button.
- To configure multiple interfaces with the same settings, select the check box associated with each interface.
- To configure all interfaces with the same settings, select the check box in the heading row.
- Click the Edit button.
The Edit OUI Port Settings pop-up window displays.
- From the Auto VoIP Mode menu, select the Auto-VoIP mode for the interface:
- Disable: The Auto-VoIP mode is disabled. This is the default setting.
- Enable: The Auto-VoIP mode is enabled.
- From the Auto WiFi Mode menu, select the Auto-WiFi mode for the interface:
- Disable: The Auto-WiFi mode is disabled. This is the default setting.
- Enable: The Auto-WiFi mode is enabled.
- From the Auto Camera Mode menu, select the Auto-Camera mode for the interface:
- Disable: The Auto-Camera mode is disabled. This is the default setting.
- Enable: The Auto-Camera mode is enabled.
- Click the Save button.
Your settings are saved.
In the OUI Port Settings section, the Auto-VLAN Mode fields show if the mode is enabled or disabled.
The Operational Status fields show if the interface for which you enabled or disabled the Auto-VLAN mode is connected to a device or administratively enabled or disabled. For example, if you enabled the Auto-WiFi mode for interface g2 mg2 xg2 but that interface is not connected to a device or is administratively disabled, the Operational Status field shows Down.