Stack firmware synchronization and upgrade

All switches in a stack must run on the same firmware.

All stack members must run the same firmware version to ensure compatibility within the stack. Firmware synchronization is always on. If a switch is added to the stack and its firmware version is different from the firmware version on the stack management switch, the stack management switch automatically synchronizes the firmware on the new switch with the version that the stack management switch is running. The synchronization operation might result in either an upgrade or a downgrade of the firmware on the mismatched switch.

Upgrading the firmware on a stack of switches is the same as upgrading the firmware on a single switch. After you download the firmware, see Update the switch software, the downloaded firmware is distributed to all the connected switches of the stack. If you are setting up a new stack, we recommend that you first upgrade the firmware on the stack management switch and then add the stack members.

Note: We recommend that you set the active firmware for all stack members the same as the active firmware of the stack management switch. In other words, if image 1 is the active image on the stack management switch, all switches must use image 1 as the active image. For information about configuring the active image, see Change the software image that loads when the switch starts.