Display the stack status

Displays the stack status of all units.

The Stack Status page displays the stack topology type, detailed status for each unit in the stack, and the status of each stacking port.

To view the stack status:

  1. Open a web browser and log in to the device UI using your login details and device admin password.

    The Dashboard page displays.

  2. Select System > Stacking > Stack Status.

    The Stack Status table displays the following information:

    Table 1. Stack status table
    Field Description
    Unit ID The identifier assigned to this switch in the stack (1 through 6).
    Switch description The model name of the switch.
    Serial Number The serial number of the switch.
    Uptime Displays the relative time since the last restart of the switch.
    Preconfigured Model Identifier This field displays the model type assigned by the device manufacturer to identify the device.
    Plugged-in Model Identifier This field displays the model type assigned by the device manufacturer to identify the plugged-in device.
    Detected Code Version This field indicates the detected version of code on this unit.
    Detected Code in Flash Displays the release number and version number of the code stored in flash.
    Priority Status The stack election priority for this switch (0 through 15). When the Priority Configuration is changed, the new value is applied only after the switch restarts. Until then, Priority Status displays the previously active value.
    Priority Configuration The switch with the highest priority becomes the stack management switch. If two switches share the same priority, the switch with the higher MAC address wins.
    Management Status The role of the unit in the stack:
    • Management: The switch acts as the stack management switch.
    • Stack Member: The switch acts as a member of the stack.
    • Standby: The standby switch of the stack. This unit takes over management duties if the primary management switch fails.
    Switch Status The status of the unit in the stack can be one of the following:
    • OK: The unit is connected and working.
    • Unsupported: The type of unit is not supported.
    • Code Mismatch: The code version is different to the management unit.
    • Config Mismatch: The unit is different from the configured switches.
    • Not Present: The unit is not connected.
    • Updating Code: A code update is in progress.
  3. To view the stack-port status for a single unit, select the unit from the Unit ID menu.
    The Stack-port Status table updates to show only the ports for the selected unit.
  4. Click the Refresh button to update the displayed status information.