Configure GARP interface settings
You can configure GARP settings for individual interfaces. These settings take effect only if the GVRP mode is enabled on the switch.
To configure GARP settings for an interface:
- Open a web browser and log in to the device UI using your login details and device admin password.
The Dashboard page displays.
- Select Switching > VLAN > GARP VLAN.
The GARP VLAN page displays.
The following steps refer to the GARP Port Configuration section.
- From the Filter By menu, select to display ports only (Ports), LAGs only (LAG), or both ports and LAGs (All).
- Select one or more interfaces by taking one of the following actions:
- To configure a single interface, select the check box associated with the interface, or type the interface number (for example, g3 ) in the Search field and click the Go button.
- To configure multiple interfaces with the same settings, select the check box associated with each interface.
- To configure all interfaces with the same settings, select the check box in the heading row.
- Click the Edit button.
The Edit GARP Port Configuration pop-up window displays.
- From the GVRP Mode menu, select to enable or disable GVRP mode for the interface:
- Disabled: The GVRP mode is disabled for the interface. The join timer, leave timer, and leave all timer options are without any effect. This is the default setting.
- Enabled: The GVRP mode is enabled for the interface.
- In the Join Timer field, type the time in centiseconds between the transmission of GARP PDUs registering membership for a VLAN or multicast group.
Enter a number between 10 and 100 (0.1 to 1.0 seconds). The default is 20 centiseconds (0.2 seconds).
- In the Leave Timer field, type the time in centiseconds that the interface must wait after receiving an unregister request for a VLAN or multicast group before deleting the associated entry.
This allows time for another station to assert registration for the same attribute to maintain uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0 seconds). The default is 60 centiseconds (0.6 seconds).
- In the Leave All Timer field, type how frequently LeaveAll PDUs are generated.
A LeaveAll PDU indicates that all registrations are deregistered. To maintain registration, participants must rejoin. The leave all period timer is set to a random value in the range of LeaveAllTime to 1.5 * LeaveAllTime. The timer is specified in centiseconds. Enter a number between 200 and 6000 (2 to 60 seconds). The default is 1000 centiseconds (10 seconds).
- Click the Save button.
Your settings are saved.