Stack firmware synchronization and upgrade

All stack members must run the same firmware version to ensure compatibility within the stack.

By default, if a switch is added to the stack and its firmware version is different from the firmware version on the stack management switch, that switch cannot join the stack. You can enable the Stack Firmware Auto Upgrade feature to automatically synchronize the firmware version on the new switch with the version running on the stack management switch. The synchronization operation might result in either upgrade or downgrade of firmware on the mismatched stack member.

Upgrading the firmware on a stack of switches is the same as upgrading the firmware on a single switch. After you download the firmware, see Update software or download a file, the downloaded firmware is distributed to all the connected switches of the stack. If you are setting up a new stack, we recommend that you first upgrade the firmware on the stack management switch and then add the stack members.

Note: We recommend that you set the active firmware for all stack members the same as the active firmware of the stack management switch. In other words, if image 1 is the active image on the stack management switch, all switches must use image 1 as the active image. For information about configuring the active image, see Change the software image that loads when the switch starts or reboots.