Configure the OUI-based interface settings

You can configure the OUI interface settings.

To configure the OUI-based interface settings:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select Switching > Auto-VoIP > OUI-based > Port Settings.

    The page Port Settings displays.

  3. Select whether to display physical interfaces, LAGs, or both by clicking one of the following links above the table heading:
    • 1 or Unit ID for a stacked switch:

      • 1: If no switch stack is configured, the physical interfaces for the switch are displayed.
      • Unit ID for a stacked switch: If a switch stack is configured, the physical interfaces for the switch with the selected stack unit ID are displayed.
    • LAG: Only LAGs are displayed.

    • All: Both physical interfaces and LAGs are displayed, or for a switch stack, both physical interfaces on all switches in the stack and LAGs are displayed.

  4. Select one or more interfaces by taking one of the following actions:
    • To configure a single interface, select the check box associated with the port, or type the port number in the Go To Interface field and click the Go button.

    • To configure multiple interfaces with the same settings, select the check box associated with each interface.

    • To configure all interfaces with the same settings, select the check box in the heading row.

  5. From the Auto VoIP Mode menu, select to enable or disable the Auto VoIP mode for the interface.

    Auto-VoIP is disabled by default.

  6. Click the Apply button.

    Your settings are saved.

    The Operational Status field show if the interface is up or down.

  7. To save the settings to the running configuration, click the Save icon.