Manage the PoE usage threshold

If your model provides power supply unit (PSU) bays (also referred to as slots), you can install one or more auxiliary power supplies (APS) to expand PoE power or enable N+1 power redundancy (see Manage N+1 power redundancy). Depending on the number of PSU bays, you can also expand PoE power and enable N+1 power redundancy.

The PoE usage threshold applies to the switch, that is, to the internal power supply and any optional APSs that are installed.

To manage the PoE usage threshold for the switch:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select System > PoE > Advanced > Power Configuration.

    The Power Configuration page displays.

  3. If a stack is configured, from the UNIT ID menu, select the ID for a stacked switch.
  4. In the System Usage Threshold field, enter a number from 1 to 99 to set the threshold level at which a trap is sent if the consumed power exceeds the threshold power.

    The value that you can set in this field is the same value that you can set in the System Usage Threshold field on the PoE Configuration page (see Set the PoE system usage threshold and power management mode).

  5. Click the Apply button.

    Your settings are saved.

The following table describes the view-only fields in the Power Status section.

Table 1. Power status information

Field

Description

Total Power Available (W)

The maximum power in watts of all installed auxiliary power supplies that the switch can deliver to all ports

PoE Threshold Power (W)

If the consumed power is below the threshold power, the switch can power up another port. The consumed power can be between the nominal and threshold power. The threshold power is displayed in watts.

Note: The threshold power value is determined by the value that you enter in the System Usage Threshold field.

Power Modules Slot

The PSU bay

Module Name

The APS model number

Status

The status of the APS:

  • Not Present: No APS is installed or detected

  • Operational: The APS is connected and works correctly

  • Failed: The switch cannot detect the status

  • Not Powered: The APS is connected but not powered on.

Power Module AC Input (V) The APS AC input voltage